RS232 Serial Interface
82
Operating Manual ProNumeric XCI 600 Version 07/16
12
RS232 Serial Interface
The serial interface is by default assigned to the real-time operating system
and is used to connect operating devices and service PCs for diagnosing the
system. The connection is made via the COM interface of the service PC
and the XCI-600 (port X 201).
It is used for the output of the bootlog when the XCI 600 is booting up, for
example. To set the necessary parameters, open the Schleicher X-Manager
(see: section 13.1.4).
Figure 87:
Setting up the terminal
program on the service
PC
Tera Term is
recommended
Please note:
Do not connect any open wires to serial interfaces (RS232, RS422) (to
which, for example, a service PC may be connected from time to time).
Open cables can cause coupling between the transmit and receive
lines, leading to malfunctions in the control process.
When not needed, pull off the corresponding connector from the
controller.