Operation
52
Operating Manual ProNumeric XCI 600 Version 07/16
"?" Menu
Figure 68:
MFA, Menu "?"
The MFA documentation can be called via the
?
menu. The help file contains
information on the program settings and command line parameters as well
as programming examples.
The
Display BootLog
menu item displays the Bootlog file of the real-time
operating system VxWorks.
6.1.4
Log files
There are two types of log files, BootLog_xx.txt and LogBook_xx.txt.
The BootLog_xx.txt file is used to record the controller's boot-up
process.
The Logbook_xx.txt file is used to record the error history.
These log files are updated at bootup time or every 24 hours.
The log files are generated with each restart of the controller. If the controller
is in continuous operation, the LogBook file is generated every 24 hours.
The storage intervals can be set between 0 and 256 hours. When set to
"Zero", no files are created.
The files are assigned a numerical index, which is incremented by one
whenever the data is saved. The maximum number is limited to 99 files. The
default setting is 10 files.
All specifications can be altered in the Schleicher Dialog under
Inbetriebnahme/Boot-Einstellungen/Sonstige
Einstellungen) (Translation: startup/boot-settings/other
settings).
Memory location and name of file:
SCHLEICHER/Os/Log/BootLog_xx.txt
SCHLEICHER/Os/Log/LogBook_xx.txt
Note
The log files are intended primarily to support diagnosis by the
controller manufacturer.