background image

How to Install

(Door thickness 40-50mm)

1. Please read the installation manual before you install the product.

2. The strike guider is served to install correctly, remove the strike guider 

    after installation. 

3. Please check door thickness and door handing before installation.           

    This product can be installed with door thickness 40-50mm

Firstly, check the door opens and closes smoothly.
Fold 90° angle on the fold line of the installation template and stick it to the 

door and mark for installation.
Drill holes as specified on template.
Where replacing existing mechanical auxiliary lock, use center hole on the 

mounting plate to adjust position and install the product.
Fasten the front using screw (M5x30, 2pcs), to fix the mounting plate (as 

required check the direction of the mounting plate). Use screw (FH1x 30, 5pcs) 

to increase the strength of the mounting plate fixing.
Pull through Front cable and connect to Back connector, and then fix to the 

mounting plate by using screw (M5x29, 4pcs).

1.
2.

3.
4.

5.

6.

7.

8.
9.

10.

Fix the strike with screw (FH1x 30, 6pcs) and ensure the deadbolt aligns 

correctly with strike.
Insert batteries (check polarity).
Check the door opens and closes properly.
Read the user’s manual to register PIN code.

*For Metal Doors: Please use the T4x19 screws instead of FH1x 30 

 (Timber Doors).

(Use on indoor side)

Installation Template  S-480

  

Please check measurements 

when printing template 

83mm

58mm

FH1x 30 (5pcs)

FH1x 30 (3pcs)

Screw

Отзывы: