P516-751

LOCK AND FOB SETUP:

 

FOB OPERATION:

 

SAFE SCHOOL BUTTON OPERATION:

 

CO-220-75 Function

Standalone Classroom Lockdown Solution

USER GUIDE AND PRODUCT SPECIFICATIONS

1) Press and hold the Safe School button for 5 seconds until the blinking green LED is observed on the 
    inside of the lock. Release the Safe School button. The green LED will continue to blink.

Note: Lock and fob are already paired when coming from the factory.

The Safe School Button is located on the Safe School Printed Circuit Board Assembly (PCBA). 

The Safe School Button can also be used to remove all paired fobs from memory.  

The Safe School  Button is used to pair and add additional fobs to the lock.

To access the Safe School Button, remove the INSIDE escutcheon cover. 

Battery Replacement

(CR 2032)

Pairing a Fob to the Lock:

NOTE:

Single fob also sold separately: #44485001

Fob Button Operation:

2) Press and hold the button on the fob. The green LED will stop blinking and turn a solid green for 
    2 seconds when pairing is complete. Release the fob button.

1) Press and hold Safe School button for 20 seconds until blinking red LED is visible on the inside of the 
    lock. Release the Safe School button. The red LED will continue to blink.

The fob has a maximum operating range of 75’.

NOTE:

When the 75 Function is in Normal Mode, it operates as a standard 
classroom lock.  Construction Access, Manual Lock Programming, and Proximity Credential 
functions all operate the same as they do for a standard classroom/storeroom lock; however, 
when the 75 Function is in Lockdown Mode, only a pass-through function may gain temporary 
access. In this state, any other credential function makes the Schlage button blink red
(12 times) and the door will not unlock.  

2 Second

Fob Press

Lockdown Mode

Red LED Blinks 4 Times and Continues to

Blink On/Off at a 

¹⁄₂

 Second Interval

Red LED Blinks 4 Times and Continues to

Blink On/Off at a 

¹⁄₂

 Second Interval

The fob may be paired with only one lock.
The lock may be paired with a maximum of 10 fobs.
It is recommended that you change the coin cell battery in the fob annually. 
The fob WILL retain all current lock pairings while changing the battery.
The fob is not an access credential. It is only used to activate/deactivate Lockdown Mode.

Erasing all Fobs from the Lock:

    and remove the battery.

1) With the fob out of range of any paired doors, open the fob housing with a screwdriver or coin 

2) Place the battery back into the fob and close the fob housing.
3) Within 1 minute of reinstalling the battery, press and hold the fob button for 5 seconds.

Erasing Lock from the Fob:

2) Press and release the Safe School button. The red LED will stop blinking and turn a solid red for 
    2 seconds once the fobs have been erased.

2 Second

Fob Press

Lockdown Mode

*See SAFE SCHOOL BUTTON OPERATION

Safe School Button

20 Second

Fob Press

Normal Mode

Green LED Blinks 4 Times

Normal Mode

Green LED Blinks 4 Times

Press and

Release

Safe School

Button*

Normal

A normal credential unlocks the door for a specified time 

Toggle

A toggle credential unlocks a door until it is locked again by a toggle credential

Freeze

A freeze credential disables the credential reader until a freeze credential enables it

Pass-
Through

A pass-through credential will momentarily unlock a door that is in Lockdown Mode 
or currently locked

While the 75 Function is LOCKED in NORMAL Mode

Button Press

Resulting State

Successful Function Change Indicator

While the 75 Function is in LOCKDOWN Mode

Credential Functions

Button Press

Resulting State

Successful Function Change Indicator

While the 75 Function is UNLOCKED in NORMAL Mode

Button Press

Resulting State

Successful Function Change Indicator

!