2 -Wire Intercom System
DT596(F)/ID User Manual
DT596/ID
DT596F/ID
DT-ENG-596(F)ID-V1 110S923
RF CARD
Страница 1: ...2 Wire Intercom System DT596 F ID User Manual DT596 ID DT596F ID DT ENG 596 F ID V1 110S923 RF CARD RF CARD ...
Страница 2: ...crophone 90 mm 28 mm 176 mm 220 mm 119 mm ID card window Camera Lens Speaker Nameplate Call Button Screws for panel mounting Microphone RF CARD RF CARD 1 Parts and Functions 2 Terminal Descriptions BUS PL S1 S2 S MIC adjustment Lock Control Jumper Door Station Code DIP Main Connect Port SPK adjustment 1 2 3 4 ON DIP JP LK RS485 Connect Port 1 2 3 1 ...
Страница 3: ... power input connect to the power positive power S1 S2 Lock power output to connect 2 locks S Lock power output connect to the power input of locks only when using the camera to power the locks if using the external power supply for the locks the S will not be connected 3 Door Station Mounting adjust camera angle 1 2 4 3 Drill holes in the wall to match the size of screws and attach the rainy cove...
Страница 4: ...tach the panel to the mounting box and use screws supplied to fix the panel Place name label Connect the cable correctly and adjust right angle for camera adjust camera angle PS Adjusting Camera Angle use a screwdriver to loosen the screw then adjust an appropriate camera angle after finishing use the screwdriver to fix the screw 3 ...
Страница 5: ... plastic cover on right left side to move away the cover insert a name paper then put the plastic cover back to the panel RF CARD 4 System Wiring and Electric Lock Connection Basic Connection AC monitor DPS PS4 L1 L2 PL S1 S2 S 4 ...
Страница 6: ...ult Door Lock Controlled with Dry Contact Note 1 The external power supply must be used according to the lock 2 The inside relay contact is restricted to AC or DC 24V 3A 3 The jumper must be taken off before connecting 4 Setup the Unlock Mode of Monitor for different lock types Power on to unlock type Unlock Mode 0 by default Power off to unlock type Unlock Mode 1 EB LOCK BUS PL S1 S2 S LOCK 2nd 1...
Страница 7: ...a1 3 S W V17 11 418 00 Local addr Unlock timing Video standard UI CODE MCM VER Updated Home Installer setup Caliber TouchScreen Code Number 0010 Remove all remote control 0011 Add remote control 8000 Set as master unit 0 8001 Set as slaver unit 1 8002 Set as slaver unit 2 8003 Set as slaver unit 3 8004 Set as guard unit 8005 Set as not guard unit 8006 Panel on as slaver unit called 8007 Panel off ...
Страница 8: ...nection 85 260VAC DPS PS5 monitors L1 L2 PL S1 S2 S L1 L2 PL S1 S2 S L1 L2 PL S1 S2 S L1 L2 PL S1 S2 S 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 2 3 4 ON 1 Camera ID 00 ID 10 ID 01 ID 11 2 Camera 3 Camera 4 Camera DBC4 A B C D BUS 7 ...
Страница 9: ...N OUT Wiring Mode Multi Monitors Connection Code 0 DIP 6 off Code 14 DIP 6 off Code 15 DIP 6 on 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON monitor monitor monitor 1 2 3 4 ON ID 00 85 260AC DPS PS5 RF CARD 8 ...
Страница 10: ...t3 The relay 2 doesn t respond the second lock showing user cards controlled two locks or pressing unlock 2nd on monitor can not release the second lock During this time After continuously showing access card 10 times the relay 2 will be closed for 60 seconds the blue LED relay 2 will be illuminated for 60 seconds and the buzzer will continuously sound If the system is connected alarm the alarm fu...
Страница 11: ... when you add or delete user cards Please keep it well for future use Bit state User Code Bit state User Code Bit state User Code Code 0 Code 6 Code 11 Code 1 Code 7 Code 12 Code 2 Code 8 Code 13 Code 3 Code 9 Code 14 Code 4 Code 10 Code 15 Code 5 Bit 1 to Bit 5 are used to User Code setting The DT596 F ID responds to 0 15 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON 1 2 3 4 5 6 ON ...
Страница 12: ...w Show the MASTER CARD ADD card to ID card window again format operation is performing red red red on blink off off off off blue blue blue beep beep beep beep beep Show the MASTER CARD ADD card to ID card window in standby mode Press CALL button At the same time show user cards to be added one by one Show the MASTER CARD ADD card to exit But it will return to standby mode if no operation within 15...
Страница 13: ...ease the first lock red indicator lights up Note2 if the user card control two locks show the user card to ID card window in standby mode the red blue indicator blink for 1 5s alternately During this time press CALL button to release the second lock Otherwise release the first lock if there isn t any operation within 1 5 seconds If 10 times unauthorized access cards are continuously attempted the ...
Страница 14: ...please use a little pure water or dilute soap water to clean the dust The unit is weather resistant However do not spray high pressure water on access control keypad directly Excessive moisture may cause problems with the unit You must use the right adaptor which is supplied by the manufacture or approved by the manufacture Pay attention to the high voltage inside the products please refer service...
Страница 15: ...tor quantity 20 Cable Usage A B C Twisted cable 2x0 75 mm2 60 60 30 Twisted cable 2x1 mm2 80 80 40 When Monitor quantity 20 Cable Usage A B C Twisted cable 2x1 mm2 70 30 20 Twisted cable 2x1 5 mm2 70 50 30 The farest monitor B A C DPS PS5 DBC DBC 4 monitor monitor monitor with two or four monitors RF CARD Note If the monitor has been specified the distance refer to the parameter 14 ...
Страница 16: ...The design and specifications can be modified without notice to the user Right to interpret and copyright of this manual are reserved DT ENG 596 F ID V1 110S926 ...
Страница 17: ...Anleitung für DT27 25 692SD TD7 Videostationen ManualDT69SD TDXXSerie DE Schick2010 ...
Страница 18: ...Geräte vor Feuchtigkeit zu hohen Temperaturen und Staub Befestigen Sie den Monitor in einer Höhe von ca 160 cm um eine optimale Sicht auf den Monitor zu gewährleisten Befestigen Sie die mitgelieferte Halteplatte mit den Schrauben an der Wand und hängen Sie den Monitor ein Anleitung für Innenstation DT27 SD TD7 Die optimale Montagehöhe für Ihren Monitor beträgt 145 160 cm Befestigen Sie die Haltepl...
Страница 19: ... Kalender angezeigt Datum Wochentage und die Uhrzeit Betätigen Sie den Bildschirm erneut und es erscheint das Hauptmenü auf den Schirm Manual Monitor Zur manuellen Auswahl Ihrer Außenstation es können hier bis zu 4 Türstationen ausgewählt und einzeln selektiert werden Auto Monitor Der Es werden alle Verfügbaren Außenstation oder und Kameras angezeigt im einstellbaren Intervallen ...
Страница 20: ...espeichert sind angezeigt werden Über den Ikon Multimedia Album Options kann die Abspieldauer der Albumanzeige eingestellt werden User Setup Hier könne Einstellungen wie Lautstärke der Klingel Nachtklingel Lautstärke Klingelton Außenstation Intercom und Türklingel noch nicht verfügbar Telefonwahlfunktion derzeit noch nicht freigeschalten Schließen des Monitors About Hier ereichen sie die Experten ...
Страница 21: ...können währen des Gesprächs den Unlockknopf Unlock oder Ikon Auf dem Bildschirm betätigen Die Standardmäßige Öffnungsdauer beträgt 5 Sekunden Sie können je nach Anlage bis zu 2 Schlösser anschließen Es werden Unlock 1 und Unlock 2 als Icon Während des Gesprächs mit dem Besucher haben sie die Möglichkeit ein Foto durch betätigen des REC Capture können Sie manuell ein Bild während des Gesprächsaufne...
Страница 22: ...Code des Monitors Rückseite Codes 1 15 oder 16 28 eingestellt werden Code 8010 Set lock Code 0 Bitte diese Einstellung so lassen Es liegt Spannung am Schloss an wenn oder wird potentialfrei geschlossen je an Anschluss Mode beim betätigen des Türöffners Code 8011 Set lock Code 1 Bei dieser Einstellung liegt immer Spannung an Beim betätigen des Türöffners wird selbige unterbrochen Standart nicht ver...
Страница 23: ...7 Inch color TFT LCD Display Auflösung 800 3 RGB 480 pixels Video Signal 1Vp p 75Ω CCIR standard Interner Bildspeicher 120M Anzahl der zu speichernden Bilder ca 800pcs inner memory 30000pcs 2G SD card Türöffner Zeit einstellbar 1 to 9 seconds set by Monitor Arbeits Temperaturbereich 10ºC 45ºC Abmessung Monitor 125 H 225 W 23 D mm Anschlussbeispiel mit DT591 Code 1 16 siehe Anleitung DT591 2 ...
Страница 24: ...nhang mit dem Vertrieb von Batterien oder mit der Lieferungvon Geräten die Batterien enthalten ist der Verkäuferverpflichtet Sie auf folgendes hinzuweisen Sie sind zur Rückgabe gebrauchter Batterien als Endnutzergesetzlich verpflichtet Sie können Altbatterien die der Verkäufer als Neubatterien im Sortiment führt oder geführt hat unentgeltlich am Versandlager Versandadresse des Verkäufers zurückgeb...