6. MAINTENANCE (ROUTINE AND SPECIAL)
6.1 Check filter cleaning
It is very important to inspect filters condition periodically.
In the system there are the following:
1. Mesh filter (strainer).
2. Pump filter (5 micron cartridge filter
– blue and white filter housing).
3. Active carbon filter.
In order to keep the filters properly clean, follow the tab illustrated hereby:
OPERATION
FREQUENCY
PROCEDURE
Check
and
clean
the
strainer
Every 5 days
Visual inspection and washing
Replace the 5 micron
cartridge filters
It depends on the working
conditions and the turbidity of the
sea water. In average conditions
the replacement of the cartridge is
recommended
every
80-100
working hours. Once replaced the
filters, it is necessary to purge the
air from the system,
opening for 2-
3 minutes the depressurization
valve.
Unscrew the filter housing counter
clockwise by using the specific key
provided
Replace the active carbon
fibre filter
Once per year
Unscrew the filter housing counter
clockwise by using the specific key
provided