5
– FUNCTIONING AND USE
COD.
35M12/24.D.2018
EN
THE PRESENT MANUAL BELONGS TO -
Schenker Italia
- ALL RIGHTS RESERVED
38
5.4 Normal operating procedure
Please, be sure to perform all the following checks before proceeding normal operating procedure:
1. Be sure the reset valve is closed (lever
orthogonal
to the body valve) and the positioner completely
unscrewed.
2. Be sure the depressurization valve is closed.
5.4.1
Normal operating procedure without timer
1. Push shortly the button START.
The controller will open the electro-valve, helping the
inlet pump hose to get filled with water. After 5
seconds the controller starts the pump.
The display will show the increasing production time.
2. Push the Stop button when finishing the
running time needed.
If the washing has been selected, the system will start
the washing procedure, and then will stop
automatically after around 1 minute.
The fresh water consumed for the automatic washing
is about 20/25 lt.
5.4.2
Normal operating procedure with timer
1. Select the needed timing (1 to 6 hours) throgh
the specific timer within the menu option (the
system will hold as well the previous setting.)
2. Push the button START for more than 3
seconds.
The display will show the decreasing production time.
The system will stop when the selected time is
reached, and then perform the automatic washing if
previously selected.
However, the system can be stopped at any time by
pushing STOP.
NOTE
It could occur
that the system doesn’t stop immediately when stop button is pushed, but it rather
stops after a while. This behaviour is absolutely normal because the electronic central unit waits for
the hydraulic clock signal before switching off in order to avoid hydraulic system block.