Dual flush WC flush valve

IMPORTANT

The SCHELL Dual flush WC flush valve must be installed to the following 
specifications:

• Requires a minimum of 

133 mm

wall cavity to finished wall and                             

a maximum of 

178 mm

.

• Inwall coverplate is suitable for a maximum wall thickness of 

25 mm

.

• 

Water supply:

Minimum delivery pipe size 25 mm with left or right connection to valve
body for 1 flush valve. For > 1 flush valve 32 mm supply pipe or according
to water service rule calculations and simultaneous demand requirements.

• 

Minimum flow: 

1,3 litres/second at the valve

• 

Maximum static pressure may not exceed 800 KPA

• 

Recommended operating pressure: 200-500 KPA (Flow pressure)