Instruction Manual for Electroblock EBL 271

2

Date: 14.02.2011

811.523 BA / EN

1 Safety information

1.1 Meaning of the safety symbols

Y

DANGER!

Failure to comply with this sign may result in danger to life and limb.

Y

WARNING!

Failure to comply with this sign may result in injury.

Y

ATTENTION!

Failure to comply with this sign may result in damage to the device or other

connected consumers.

1.2 General safety instructions

The design of the device is state-of-the-art and complies with approved sa-

fety regulations. Failure to observe the safety instructions may nonetheless

result in damage to the device or injury to persons.

Only use the device when it is in perfect technical condition.

Any faults that may affect the safety of persons or the proper functioning of

the device must be repaired immediately by specialists.

Y

DANGER!

230 V unit carrying mains voltage.
Risk of fatal injury due to electric shock or fire:

F

Do not carry out maintenance or repair work on the device.

F

If cables or the device housing are damaged, no longer use the device

and isolate it from the power supply.

F

Ensure that no liquids enter the device.

Y

WARNING!

Hot components!
Burns:

F

Only change blown fuses when the device is completely de-energised.

F

Blown fuses may only be replaced when the cause of the fault is

known and rectified.

F

Never bypass or repair fuses.

F

Only use original fuses rated as specified on the device.

F

Device parts can become hot during operation. Do not touch them.

F

Never store heat sensitive objects close to the device (e.g. tempera-

ture sensitive clothes if the device has been installed in a wardrobe).

Содержание Electroblock EBL 271

Страница 1: ...al Electroblock EBL 271 Table of contents 1 Safety information 2 1 1 Meaning of safety symbols 2 1 2 General safety information 2 2 Introduction 3 3 Operation 3 3 1 Starting up the system 3 3 2 Changing the battery 4 3 3 Operating faults 5 3 4 Closing down the system 7 4 Application and functions in detail 8 4 1 Battery functions 9 4 2 Additional functions 10 5 Maintenance 10 Appendix 11 ...

Страница 2: ...ay affect the safety of persons or the proper functioning of the device must be repaired immediately by specialists Y DANGER 230 V unit carrying mains voltage Risk of fatal injury due to electric shock or fire F Do not carry out maintenance or repair work on the device F If cables or the device housing are damaged no longer use the device and isolate it from the power supply F Ensure that no liqui...

Страница 3: ... or when retrofitting accessories see Section 3 2 and the installation instructions for the EBL 271 3 1 Starting up the system Y ATTENTION Incorrect electroblock settings can result in damage to connected devices Therefore prior to starting F Ensure the living area battery is connected F Ensure that the battery selector switch Fig 3 Pos 9 is set to the correct position for the battery installed Us...

Страница 4: ...troblock to 12V power supplies with rechargea ble 6 cell lead gel or lead acid batteries Do not use any unsuitable battery types Y Normally only batteries of the same type and capacity should be used i e the same as those installed by the manufacturer Y It is possible to swap lead acid batteries with lead gel batteries However swapping from lead gel batteries to lead acid batteries is only possibl...

Страница 5: ...aults A fault in the power supply system is usually caused by a blown fuse Please contact our customer service department if you cannot rectify the fault using the following table If this is not possible e g if you are abroad you can have the electroblock repaired at a specialist workshop In this case you must ensure that the war ranty is not invalidated by incorrect repairs being carried out and ...

Страница 6: ...onsumers not required Defective electroblock Contact customer service Living area battery is not h d d i bil Defective alternator Check the alternator g y charged during mobile operation battery voltage No voltage on D input Check the fuse and wiring operation battery voltage below 13 0 V D switch on the electro block is not set correctly Set the switch according to the D signal from the vehicle 1...

Страница 7: ...cessive ambient temperature or lack of ventilation Always prevent the device from overheating nevertheless Y If the automatic shutdown mechanism of the battery monitor is triggered fully charge the living area battery 3 4 Closing down the system A battery is isolated by switching off the main switch on the IT LT con trol and switch panel and by disconnecting a plug connector Y ATTENTION Damage to ...

Страница 8: ...F the 12V distribution unit F fuses for the 12V circuits An IT or LT control and switch panel must be connected for operation These devices control the electrical functions in the vehicle s living area inc luding accessories There is also an option to connect an additional charger and a solar charge regulator Flat vehicle fuses protect the various circuits The two D outputs and the output for the ...

Страница 9: ... gel and lead acid With LT control and switch panel approx 4 mA depending on the control and switch panel used under the following condi tions F No mains connection F Living area battery voltage 12 6V F 12V main switch OFF Living area battery Characteristic charging curve IUoU End of charge voltage 14 3V Charging current 18A Voltage for float charge 13 8V with automatic switch function Starter bat...

Страница 10: ... 230V mains is connected to the electroblock This output is suitable for supplying the side marker lights of the motorhome The associated voltage output is switched on as soon as control signal Ve hicle lighting ON of the basic vehicle is applied at the relevant control input of the EBL 271 This output provides a supply voltage to operate an electric fold away bed The voltage is only applied when ...

Страница 11: ... the basis for this declaration application submitted for appro val date 04 2010 Typgen no e1 72 245 2009 19 5664 __ EC gen mark e1 035664 Schaudt GmbH Elektrotechnik Apparatebau Planckstraße 8 88677 Markdorf Germany B Special fittings accessories Schaudt IT LT switch panel required for operation C Customer service Schaudt GmbH Elektrotechnik Apparatebau Planckstraße 8 D 88677 Markdorf Phone 49 75...

Страница 12: ...pe _______________________ Item no _______________________ Vehicle Manufacturer _______________________ Model _______________________ Own installation Yes No Upgrade Yes No Upstream overvoltage protection Yes No Following fault has occurred please tick Electrical consumers do not work which please specify below Switching on and off not possible Persistent fault Intermittent fault loose contact Oth...

Страница 13: ... 1 2 lighting continual positive for radio 4 Block 5 D input output battery sensor 5 Block 4 Consumers not connected 6 Block 3 Additional charger 7 Block 2 Solar regulator 8 Block 1 Refrigerator 9 D signal changeover switch 10 Selector switch for acid gel battery 11 Assembly flaps 12 Flat vehicle fuses 13 Mains connector 14 Housing 1 2 3 Fig 4 Layout of EBL 271 electroblock rear 1 Connector for li...

Страница 14: ...Minifit SR 4F block 1 batt 1 for refrigerator Minus batt 1 for Negative refrigerator Refrigerator lines must be routed separately from other battery lines to the battery terminals Refrigerator refrigerator 20A Negative living area battery sensor sensor living area battery D input MNL socket 4F block 5 D point 2A 2A D point Pump Connected negative pole of pump Light 1 Light 2 Spare 1 MNL socket 12F...

Отзывы: