5. Technical Data
Main power supply
Working Voltage
Receiver board
Installation
Operating Temperature
Dimension
230V AC, 50Hz/60Hz
24 V DC
433.92 MHz; memory for 200 transmitters
Wall mounted vertically
-20
℃
~ +50
℃
(Mechanics can still freeze at low °C and impair operation)
275mm * 195mm * 102mm
M2-
M1-
Lat-
Lit-
Lit+
M2+
M1+
Lat+
Q17
K5
K3
K2
K1
J4
F1
NC
NO
CO
+
-
-
NC
-
+
CO
NO
NC
NC
NO
CO
+
-
-
1
2
3
4
5
6
7
8
6. Troubleshooting
Error
Root cause
Resolutions
Gate reverses
1. A & B dimensions not
adhered to.
2. Gate size wrong.
1. A & B installation dimensions to align.
Correctly = between 120-190 mm (see
installation instructions).
2. W x H x weight - see technical
specifications on each drive.
System learning will not start
1. Photocell connected
incorrectly or is not
recognized by the control
board.
1.
Check the connection of the photocell
(see page
32
).
2.
Adjust photocell alignment.
3.
If the photocell is not desired (not
recommended), disable function in the
menu.
Automatic timer cannot be set 1. Photocell not found.
1. Connect photocell. This function is only
possible with a connected photocell.
Gate opens and closes by itself 1. Installation next to power
line.
1. The controller may not be mounted in
the immediate vicinity of a power line
(electrostatic charge).
N-L appears on the display
after the remote control has
been taught in
1. System is not programmed.
1. Perform system learning (see page
26
).
33