Operating and maintenance instructions
Transport and storage
Version 1.0
Page 15 of 56
3.3 Storage
Danger of property damage
Improper handling during transport and storage can cause damage.
Avoid vibrations, falls and humidity during transport
Strictly follow all instructions in these operating and maintenance instructions
and document this to maintain the manufacturer's warranty
If the motor is exposed to external influences such as temperature fluctuations,
humidity, aggressive chemicals, etc. during storage, damage can occur inside
the motor, in the roller bearings, in the terminal box and in the winding;
the components oxidise, the grease ages and the insulation resistance drops to
an inadmissible value
3.3.1 Ambient conditions
The motor must be stored in a dry, vibration-free and dust-free location in a building at
an ambient temperature above 5 °C. If other conditions apply, please contact
Schabmüller GmbH.
3.3.2 Storage location for prolonged storage
The following instructions apply to motors that are stored for long periods of time or
are taken out of service for more than two months.
The following points must be taken into account when selecting the storage location:
The room must be closed and covered
The room must be protected against moisture, vapours, rodents and insects
The room must not contain any corrosive gases such as chlorine, sulphur dioxide
or acids
The room must not be subject any heavy continuous or intermittent vibrations
The ambient temperature must be between 5 °C and 60 °C
The ambient temperature must not fluctuate suddenly
The relative humidity must be less than 50%
The room must be protected against dirt and dust deposits
The room must be equipped with a fire protection system
If the storage room does not meet one of these requirements, Schabmüller GmbH
proposes to provide the packaging with special protective measures during the
storage period:
Closed box or similar packaging
If there is a risk of fungal attack or formation, the box must be protected at the
storage location by spraying or painting with suitable chemical agents
The packaging must be carried out with great care by qualified persons
3.3.3 Logging during storage time
The motor in storage must be checked at regular intervals. A log should be kept of the
findings. The following points must be checked:
Damage
Soiling
Condensation formation
NOTICE