17. Transportation & Storage

Malfunction Due to Transport Damage

On delivery the carton containing the unit must be examined for signs of transport 

damage. Any transport damage to the carton could indicate that the unit itself has 

been damaged in transit, which in the worst case could mean that the unit will not 

function.

During transport and storage the cooling unit must be kept in the position marked on the box and at a temperature between 

-40˚F and 158˚F and a relative humidity of max. 95% (at 77°F). In case of damaged packaging after transport or in-house 

handling, we recommend controlling the unit for any internal damages

.

18. Parts Supplied

1 x Peltier Cooling Unit
1 x Instruction Manual
1 x CE Conformity Declaration
8 x Screws M6*10
8 x M6 Nuts
8 x Washers

2 x Plastic Dummy Plugs

Saginaw Control and Engineering

95 Midland Road
Saginaw, MI 48638-5770
Phone: (989) 799-6871
Fax: (989) 799-4524 

[email protected]

Содержание Enviro-Therm SCE-TE680B24VSS

Страница 1: ...Technical Data p 5 7 Performance Graph p 6 8 Mounting p 7 9 Cutout Dimensions p 8 10 Dimensions H x W x D p 9 11 Electrical Connection p 10 12 Wiring Diagram p 11 13 Taking Into Operation p 12 14 Repair p 12 15 Maintenance Cleaning p 12 16 Maintenance p 13 17 Transportation Storage p 14 18 Parts Supplied p 14 19 Warranty Limits of Liability p 15 User Manual SCE TE680B24VSS ...

Страница 2: ...ctric shock danger Important Safety Instruction Indicates instructions for safe maintenance and operation of the unit Attention Indicates possible burns from hot components Attention Indicates possible damage to the unit Instruction Indicates possible danger to the environment 2 Legal Regulations Liability The information data and instructions contained in this instruction manual are current at th...

Страница 3: ...ty regulations One can find dangerous voltage above 50V AC or above 100V DC Behind the control cabinet doors On the power supply in the unit housing The units have to be fused according to the type plate and the wiring diagram Switch the unit off immediately if the electric power supply is interrupted Danger Through Incorrect Work on the Unit Only specialized personnel are allowed to maintain and ...

Страница 4: ... having a specific polarity controller Peltier cooling units are resistant to extreme ambient conditions and can operate effectively even in environments which are dusty and oily and where temperatures may vary from 4 F to 149 F For the cooling capacities and environmental ratings please refer to the type plate data 5 Functional Principle Functional Principle The thermoelectric elements create a t...

Страница 5: ...terial Stainless Steel AISI 304 Dimensions H x W x D 15 7 x 7 1 x 6 7 inch Cutout Dimensions 14 60 x 6 10 inch Weight 22 lbs Rated Operating Voltage 24V DC Rated Current 10 8 A Starting Current 17 0 A Max Current 11 6 A Nominal Power 95 F 95 F 260 W Max Power 280 W Fuse Rating 16A T Time Delayed Slow Acting Circuit Breaker MCB Type D or K Slow Acting 16A Slow Acting Connection Connection Terminal ...

Страница 6: ...e F 4 6 16 26 36 46 56 66 76 86 96 106 116 126 136 146 2800 2600 2400 2200 2000 1800 1600 1400 1200 1000 800 600 400 200 0 20 14 9 3 2 8 13 19 24 30 36 41 47 52 58 63 820 762 703 645 586 527 469 410 352 293 234 176 117 59 0 Thermoelectric Cooler 680 BTU HR 199 Watts Heating Performance Curve SCE TE680B24VSS Enclosure Air Temp Ambient Temperature C Watt Ambient Temperature F 0 10 20 30 40 50 60 70 ...

Страница 7: ...the enclosure itself When all mounting preparations are complete the actual mounting operation can commence Only use the enclosed material to mount the unit on the cabinet Proceed as follows to mount the unit on the enclosure Set the unit up on the enclosure Ensure that the electrical connection is above the internal fan Unit without duct screw the M6 locknuts washers into the M6 set screws in the...

Страница 8: ...NTROL ENGINEERING A C USER MANUAL back to top 9 Cutout Dimensions Note Primary dimensions in millimeters Secondary dimensions in inches 300 11 81 370 14 57 386 15 2 400 15 75 155 6 1 168 6 61 180 7 09 Ø 8 Ø 0 3 1 TOP ...

Страница 9: ...B 9 SAGINAW CONTROL ENGINEERING A C USER MANUAL back to top 10 Dimensions H x W x D ...

Страница 10: ... Connection to the main electricity supply The mains connection is made via a cable To connect the unit to the mains supply proceed as follows Disconnect the control cabinet from the mains See the connection details on the circuit diagram Note the connections on the four pole terminal block from the following table Terminal 24 V DC 1 Ambient Fan 2 Ambient Fan 3 Internal Fan 4 Internal Fan 5 Thermo...

Страница 11: ...o top 12 Wiring Diagram Part List TE Thermoelectric Elements Peltier IF Internal Fan AF Ambient Fan 24 VDC Thermostat 0 VDC 1 2 3 4 5 6 TE AF IF Ambient Fan 1 2 3 4 5 6 Internal Fan Thermoelectric Elements 24 VDC Thermostat SCE TEMEVDC Thermostat SCE TEMNO ...

Страница 12: ...ny work on the unit Only qualified personnel may conduct any maintenance work on the cooling unit All Peltier units are virtually maintenance free with no filters that need to be cleaned or replaced Check the ambient heat sinks from time to time In case they are dirty proceed as following Disconnect the enclosure from the mains Clean the heat sink profile as required by blowing it out with compres...

Страница 13: ...ctrical Voltage Ensure that for the duration of the work the unit and the cabinet are disconnected from the electrical supply and protected against unauthorized reconnection Disconnect the unit from the mains Remove the unit cover Remove the screws from the relevant fan Mount the new fan Danger Through Incorrect Work Make sure that the cabinet fan or the ambient fan are not misplaced in the unit a...

Страница 14: ... transport and storage the cooling unit must be kept in the position marked on the box and at a temperature between 40 F and 158 F and a relative humidity of max 95 at 77 F In case of damaged packaging after transport or in house handling we recommend controlling the unit for any internal damages 18 Parts Supplied 1 x Peltier Cooling Unit 1 x Instruction Manual 1 x CE Conformity Declaration 8 x Sc...

Страница 15: ...not exceed minimum and maximum rated temperatures Must not exceed BTU Hr rating Filters must be cleaned regularly Must be installed and grounded in accordance with all relevant electrical and safety codes as well as the National Electric Code and OSHA rules and regulations Must be installed in a stationery application free of vibration Our warranty does not warranty product that has been modified ...

Отзывы: