9066 SCB Bell Module

Introduction
The 9066 SCB bell module is designed to replace most of the current standard bell
modules in external bells/sounders. The on-board battery supplies all the current required
to drive a bell/sounder and strobe. When the sounder is not working, the control panel
trickle charges the module's battery.
The 9066 contains an internal timer that switches off the output after 20 minutes (in line
with current UK insurance requirements). The timer can be disabled by cutting link LK1
on the pcb. The pcb provides test pins that allow you shorten the timer to 15 seconds for
testing.
As supplied from the factory:

°

The trigger input is -ve removed. The module can be converted to -ve applied trigger
by cutting link LK2 on the pcb.

°

The tamper return is -ve. This can be converted to +ve tamper return by cutting link
LK3 on the pcb.

Installation Instructions

Figure 1. 9066 SCB Bell Module

Specification
Dimensions

w = 110mm, h = 50mm, d = 27mm (Pcb ONLY, incl. battery)

Battery:

7.2 volt DEAC @ 280 mAH

Quiescent Current:

30mA (battery charged ),  45mA (battery charging)

Max Output Current:

500mA (approx) @ 7.2 volts

Built-in Duration timer: 20 

±

4 minutes

Wired inputs for:

Tamp - Closed circuit Enclosure Tamper switch,
Trig - Trigger, link selectable -ve Applied or Removed.

Wired Outputs for:

O/P +ve/-ve - output to Sounder/Strobe
Tamp Ret - Tamper Return, link selectable -ve or + ve return.

496210  Issue 2

Scantronic Limited  Perivale Industrial Park,  Greenford,  Middlesex UB6 7RJ

Trig

1234

1234

1234

1234

1234

1234

1234

1234

1234

1234

1234

1234

1234

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345

12345

20 min

7.2 volt 280 mA

DEAC battery

Test

- Hold

Batt -ve

Tamp Ret

Trig

Tamp

+ Hold

- ve

+ ve

O/P

IC1

Cut for Continuous operation (Untimed)

Cut for + ve Tamper Return

Cut for - ve APPLIED trigger input

Power On LED

Tamp Ret

IC2

LK1

LK3

LK2

Отзывы: