10 Commands And Functions
549
innovators for industry
List Multi-
Command
timed_para_mark_rel_3d
Function
moves the laser focus for the specified marking duration along a 3D vector from the
current position to the specified position (relative coordinate values) within a three-
dimensional process volume and, simultaneously as well as linearly, changes the signal
parameter selected via
to the specified value.
Restriction
If the 3D option is not enabled or no 3D correction table has been assigned (see
), then the command will have the same effect as
However, microvectorization will be calculated like a 3D command and hence will
influence the effective marking speed in the XY plane.
Call
timed_para_mark_rel_3d( dX, dY, dZ, P, T )
Parameters
dX,dY,dZ
relative coordinates of the mark vector end point in
bits
as signed 32-bit
values; allowed range:
• for
X
and
Y
: [–8388608 … 8388607] (out-of-range values will be edge-
clipped). The complete value range [–8388608 … 8388607] is only usable
as a virtual image field e.g. for (enabled) Processing-on-the-fly applica-
tions. The current coordinates will be clipped to [–524288 … 524287] (real
image field size) during runtime directly prior to use of the correction table.
• for
Z
: [–32768 … 32767] (out-of-range values will be edge-clipped).
P
End value of the signal parameter as an unsigned 32-bit value; allowed range:
dependent on the selection made via
Ctrl
parameter),
identical with
(
Value
parameter)
T
duration of the complete mark vector in
microseconds
(as a 64-bit IEEE
floating point value); allowed range: [0 … 167772160]; the parameter will be
rounded to an integer-multiple of 10; out-of-range values will be clipped.
If
T
< 5, then
timed_para_mark_rel_3d
behaves like
.
Comments
• The coordinates for the mark vector’s end point are to be supplied as relative coordi-
nates with respect to the current position. Otherwise, the command is identical to
(see the comments there, exception:
T
< 5, see above).
• The command occupies two list buffer positions. The initial component executes as an
undelayed short list command before the primary component (a normal list command).
RTC
®
4
RTC
®
5 new command
In RTC
®
4 compatibility mode, the RTC
®
5 multiplies the specified value for the X and Y
coordinates by 16 (the permissible range of values is correspondingly reduced). The value
range for Z coordinates is identical for the RTC
®
5 mode and the RTC
®
4 compatibility
mode.
Version info
• Available beginning with version DLL 517, OUT 516, RBF 512
• Last change with version DLL 518
References
,
,