8.6.4 Adjustment
SCANLAB calculates 3D correction tables so that the
plane of the focus mid-position (without setting an
offset via
,
or
) is achieved
with z = 0. Particularly when the 3-axis scan system
(with its respective 3D correction table) is intended
for maintaining the laser focus in a specific plane, you
must therefore adjust the mechanical distance
between the scan system and the working plane so
that this plane coincides with the z = 0 plane. If the
mechanical distance is different, then the laser focus
(at least at the edges of the working field or volume)
might not be sharp.
For the vario
SCAN
and vario
SCAN
de
, you’ll also need
to maintain a specific distance to the scan system.
The needed mechanical distances can be obtained
from the 3-axis scan system’s or the vario
SCAN
’s user
manual. Usually, the working distance used for calcu-
lating a correction table can also be queried via
Once the working distance and any distance to the
scan system are correctly adjusted, then the focus
position should be fine-tuned. For this, scan a test
pattern onto the middle of the z = 0 working plane.
The optimum focus position for processing results
can be achieved:
• with a vario
SCAN
and a vario
SCAN
de
by manually
adjusting the focusing ring,
• with a vario
SCAN
FLEX
by adjusting the focusing
optic’s position via the command
• with a vario
SCAN
FC (also with an intelli
WELD
®
FC) by adjusting coefficient
A
of the assigned 3D
correction table
(1)
.
Checking the Z-Axis Calibration
The optimum output values for the Z-axis also
depend on various parameters such as beam diver-
gence of the used laser and tolerances of the optical
components. Such data is generally not available to
SCANLAB and therefore not reflected in calculating
3D correction tables.
Therefore, in some cases the pre-calculated
correction table might not fit optimally to the indi-
vidual scan system. To test whether this is the case,
run a laser marking test application that covers the
entire image field. Check if the laser focus meets the
requirements of your application. If you find that the
spot diameter varies considerably, it might be
necessary to re-calibrate the Z-axis correction.
Here, the user can adjust coefficients
A
,
B
and
C
of
the parabolic function (
z
out
=
A
+
B
l
+
C
l
2
) that
determines the relationship between the Z output
value
z
out
and the focus length value
l
. Here, for each
point
(x|y|z)
in the working volume, the (unit-free)
focus length value
l
corresponds to the focus length
difference between the specified point
(x|y|z)
and
the point
(0|0|0)
. The aim of the Z-axis calibration
procedure is to determine suitable coefficients
A
,
B
and
C
. These coefficients can be subsequently trans-
mitted to the RTC
®
5 with the command
.
(1) Coefficients
A
,
B
and
C
can be queried via
and
. Only
A
should be modified.
B
and
C
should be transmitted unchanged – as queried – via