1.
Turn off the power supply. Note that if the lamp is replaced while it is still hot, protective
gloves may be required.
2.
Unscrew the filter assembly from the front of the auxiliary light.
Do not undo the grubscrews
which hold the filters in place
.
3.
The lamp is connected to the lampholder, which is hard-wired back to the connector block.
Gently extricate the lamp and lampholder on its lead from the housing, using a flat-bladed
screwdriver if necessary.
4.
Remove the old lamp from the lampholder.
5.
Replace the lamp with one of the exactly the same specifications. If in doubt, contact Scan
Optics for a replacement. Push it firmly into the lampholder, ensuring that it is seated squarely
against the base. Push the lamp back into its normal position, checking that the wires do not
interfere with the fan at the rear of the auxiliary light.
6.
Carefully screw the filter assembly back into the housing. The filter assembly has a fine-pitch
thread which may be damaged easily if it is inserted incorrectly. Do not force the thread;
instead make sure that the filter assembly is being screwed straight into the housing.