64/90
User manual SCAIME:
NU-Soft-eNod4F-E-0716_235704-C.doc
13.2.5
Logical outputs 1&2 assignment
The following table describes the possible assignments.
bits
meaning
note
b3 b2 b1 b0
output 1 assignment
0000
None
the output level does not vary
0001
Set point 1
functioning described by the ‘set point functioning’
setting and by the ‘set point 1 high and low values’
0010
Motion
copies the motion flag of the status bytes (cf. § status
register)
0011
Defective measurement
reflect the internal alarm flag describe
d in “Weighing
diagnosis” § in the MEASUREMENT AND STATUS §
0100
Input 1 image
copies input 1 level
0101
Level on request
output 1 level is driven by the ‘OUT1
activation/deactivation’ functional command (cf. §
functional commands)
0110
Cycle in progress
In loss in weight feeder mode
0111
External totalizer
In loss in weight feeder mode
1000
Flowrate alarm
In loss in weight feeder mode
1001
Batch complete
In loss in weight feeder mode
1010
Refilling in progress
In loss in weight feeder mode
1011
Extraction activated
In loss in weight feeder mode
1100
Volumetric phase
In loss in weight feeder mode
b4
output 1 logical
0
negative logic
defines the output level when enabled
1
positive logic
b11 b10 b9 b8
(or b3 b2 b1 b0 in
CANopen®)
output 2 assignment
0000
none
the output level does not vary
0001
set point 2
functioning described by the ‘set point functioning’
setting and by the ‘set point 2 high and low values’
0010
motion
copies the motion flag of the status bytes (cf. § status
register)
0011
defective measurement
reflect the internal alarm flag described in “Weighing
diagnosis” § in the MEASUREMENT AND STATUS §
0100
input 2 image
copies input 2 level
0101
level on request
output 2 level is driven by the ‘OUT2
activation/deactivation’ fu
nctional command (cf. §
functional commands)