SBS-2510  Digital Density  Meter

 

Meter

 

15

 

 

 

5   Press the 

Start

 button.  Y ou will  see a message appear 

Connecting to the USB Flash Drive

 

and receiv e an audible  beep when  the transf er of  data is completed. 

 

Note

: This method  exports all data stored in the memory  of the SBS-2510  into a single file that 

can be accessed via Microsoft Excel. 

6.1.2   Bluetooth export of results to SBS-6500 battery resistance tester

 

 

1   Insert the supplied Bluetooth dongle  into the USB port of  the SBS-2510.

 

 

2   Press the 

Results

 button on the main screen of  the unit.  

3   Press the 

Report

 button on the Results screen of  the unit.  

4   Under report options, Select 

SBS-6500

  using the Nav igation Joy stick s o print option is 

selected to SBS-6500  and  press the 

OK

 button. 

5   Press the 

Start

 button.  Y ou will  see a message appear 

Connecting to Bluetooth Dongle

 

and receiv e an audible  beep when  the connection is established. 

6   Y ou will  see a message 

Initializing Bluetooth Dongle

 appear and then the screen will 

adv ance to 

Waiting for SBS-6500

 

7   Press the 

SG Upload

 button of  the SBS-6500  unit and f ollow the procedure  f or importing 

specif ic grav ity readings and sav ing them in the correct battery  string location.  (Guidance  on 
the operation of  the SBS-6500  unit is in its own  operating manual.)  Below  is a link f or the f ull 
SBS-6500  Battery  Analy zer Manual) 

https://www.sbsbattery .com/media/PDFs/SBS-6500-Battery -Analy zer-Manual.pdf

  

 

Note

: All readings  stored in the memory  are transferred at the same  time. 

7  Maintenance

 

In this chapter y ou f ind descriptions of  the maintenance tasks y ou should perf orm on y our SBS-
2510. Any  other maintenance tasks need to be perf ormed by  a serv ice technician that has been 
qualif ied by  Storage Battery  Sy stems, LLC .

 

If  y ou experience problems with y our SBS-2510,  contact y our authorized  Storage  Battery  Sy stems, 
LLC Sales or serv ice representativ e.

 

SBS recommends that a prev entiv e maintenance and  calibration certif ication is done at least once 
a y ear through y our authorized  SBS  sales or serv ice representativ e. 

https://www.sbsbattery .com/sbs -2510-digital-battery -hydrometer.html

 

7.1   Maintenance schedule

 

If  the standard operating procedures  of  y our company  require other maintenance  interv als, use the 
interv als listed in the standard operating procedures.

 

 

Daily  

  Clean the measuring cell at the end 

of  the work day .

 

[Clean the measuring 
cell 

Page  16]

 

 

Perf orm a test with deionized  water. 

[Check the measurement 
accuracy  

Page 17]

 

 

 
 

Frequency 

  Task 

See

 

Содержание SBS-2510

Страница 1: ...SBS 2510 Digital Density Meter User Manual 1 800 554 2243 www sbsbattery com Test sbsbattery com...

Страница 2: ......

Страница 3: ...and numbers 10 5 4 Typical phasesof density determinations 11 5 4 1 Fill the measuringcell andmeasure the density 11 5 4 2 Prepare the measuring cell for the next sample 12 5 5 Example Density determi...

Страница 4: ...hydrometer html If y ou hav e any additional questions contact y our authorized SBS sales representativ e or dealer Conventions and symbols Note For usef ul inf ormation about the product Ref ers to a...

Страница 5: ...e complies with Industry Canada license exempt RSS standard s and part 15 of the FCC Rules Operation is subject to the f ollowing two conditions 1 this dev ice may not cause interf erence and 2 this d...

Страница 6: ...t is not handled correctly 1 Do not store or use the battery at temperatures below 20 C or abov e 60 C 2 Do not subject the battery to mechanical stresses like pressure bending or impacts Damage to th...

Страница 7: ...if the sample pump is f illed or empty 6 Filling tube To f ill and drain the measuring cell 7 Filling opening with locking screw To f ill and drain the measuring cell using a sy ringe The locking scr...

Страница 8: ...or result and the temperature of the measuring cell 5 Sampling ribbon Display s the current status of the sample pump or sy ringe 6 Key f unctions ribbon Display s the f unction of the key s 3 2 2 Ic...

Страница 9: ...sy ringe f illing tube Washer Battery Li Ion 2400mAh 2510 TUBE 190 User Manual 4 2 Unpack the SBS 2510 1 Remov e the SBS 2510 f rom the protectiv e packaging 2 Store the packing material f or later t...

Страница 10: ...is cov ered or in a container it is not suf f iciently cooled and ov erheats 1 Do not cov er the AC adapter 2 Do not put the AC adapter in a container Assemble the AC adapter 1 Slide the desired set o...

Страница 11: ...ss the Menu key 2 Nav igate to Settings Measurement Sampling The Sampling window opens 3 Nav igate to Sample pump 4 Press the OK key 5 Nav igate back to the home screen The icon is display ed in the s...

Страница 12: ...te to a desired menu mov e the nav igation joy stick up or down 3 To nav igate to a submenu of the selected menu mov e the nav igation joy stick to the right 4 To go back mov e the nav igation joy sti...

Страница 13: ...easuring cell alway s contains residue f rom the prev ious sample or the cleaning solution it is important that y ou remov e the residue using the new sample This is only possible if the residue is so...

Страница 14: ...ters show y ou how to conf igure and perf orm a density determination of deionized water at room temperature 77 0 F 25 C Summaryof the configuration Guided density determination Filling and draining w...

Страница 15: ...to drain the measuring cell Printout None The result is not printed 5 5 2 Perform the density determination Start the method The SBS 2510 is set up to work with the sample pump The piston is in the lo...

Страница 16: ...BS 6500 6 1 Saving and exporting data Measured results are stored in the memory of the SBS 2510 Digital Density Meter These results will remain stored in memory ev en af ter transf er has been complet...

Страница 17: ...ng them in the correct battery string location Guidance on the operation of the SBS 6500 unit is in its own operating manual Below is a link f or the f ull SBS 6500 Battery Analy zer Manual https www...

Страница 18: ...ple there is a risk that the measuring cell can be damaged by the sample To prev ent such damages SBS recommends that y ou clean the measuring cell at the end of each sample series To clean the measur...

Страница 19: ...check the measurement accuracy of the SBS 2510 y ou need to conf igure and perf orm a test 7 3 1 Example Test with water The f ollowing chapters show y ou how to conf igure and perf orm a guided test...

Страница 20: ...ps when the piston is in the uppermost position 3 Hold the f illing tube ov er the waste beaker 4 Press the OK key The sample pump starts and stops when the piston is in the lowermost position 5 Clean...

Страница 21: ...ment data and repeat the test 7 If the test continues to f ail perf orm an adjustment See also Clean the measuring cell Page 16 7 4 Replace the battery The SBS 2510 works with a rechargeable 2400 mAh...

Страница 22: ...peratures of 4 122 F 20 50 C But the lif espan of the battery is reduced when it is stored at high temperatures 1 Clean the measuring cell 2 Shut down the SBS 2510 3 Clean the housing 4 Store the SBS...

Страница 23: ...Measuring cell Borosilicate glass Parts in contact when working with sample pump PTFE poly tetraf luorethy lene PVDF poly v iny lidene dif luoride EPDM ethy lene propy lene diene monomer M class rubb...

Страница 24: ...cm3 Repeatability 0 0005 g cm3 Resolution 0 0001 g cm3 Temperature Range f or sample 32 122 F 0 50 C Resolution 0 1 F 0 1 C Accuracy 0 3 F 0 2 C 1 For v iscosity range of 0 200 mPa s Measurement scal...

Страница 25: ...SBS 2510 Digital Density Meter Meter 23 Characteristic Value Brix d w w Range 0 0 85 0 w w Accuracy 0 3 w w Plato Range 0 0 85 0 P Accuracy 0 3 P...

Страница 26: ...24 SBS 2510 Digital Density Meter Meter...

Страница 27: ...SBS 2510 Digital Density Meter Meter 25...

Страница 28: ...SBS 2510 Users Manual Rev 04 20 IOM2510 April 2020...