FORCED AIR DISTRIBUTION KIT INSTRUCTIONS  

AC01340 

 

INSTALLATION 

INSTRUCTIONS 

 

 

 

This  manual  is  available  for  free  download  on  the  manufacturer’s  web  site.  It  is  a  copyrighted 
document.  Re-sale  is  strictly prohibited.  The  manufacturer  may  update  this  manual  from  time  to 
time  and  cannot  be  responsible  for  problems,  injuries,  or  damages  arising  out  of  the  use  of 
information contained in any manual obtained from unauthorized sources. 

Содержание AC01340

Страница 1: ...ilable for free download on the manufacturer s web site It is a copyrighted document Re sale is strictly prohibited The manufacturer may update this manual from time to time and cannot be responsible...

Страница 2: ...30414 1x 1x 3x 30131 Type A metal screw 10 X 1 2 Pan Quadrex 30153 Type A self tapping metal screw 8 X 1 2 Pan Square Tek Black 30154 Type A metal screw 10 X 5 8 Square 5x 2x 1x Other accessories requ...

Страница 3: ...connection of the forced air kit to a furnace duct is prohibited unless local building codes allow it This type of installation is allowed in the USA UL 391 Standards However do not connect any hot a...

Страница 4: ...4 Figure 1 Forced Air Distribution Kit...

Страница 5: ...air outlet can be connected on either side or rear of the unit Remove the knock out on the selected side 2 If the metal tabs did not come out with the knock out cut or file the remaining tabs on the p...

Страница 6: ...6 3 Cut out the insulation to the size of the opening 4 Cut a notch on the perimeter of the adaptor as shown...

Страница 7: ...gn the adapter notch with the fireplace warm air outlet notch and turn until the flange is fully inserted The adapter is well in place when its flange is completely inserted and the adapter can rotate...

Страница 8: ...tioned at a minimum distance of 3 feet from the fireplace and outside of its enclosure Note The length of the insulated flexible pipe between the fan and the air outlet must be no less than 12 feet No...

Страница 9: ...se the same procedure to secure the insulated flexible pipe to outlet of the heat distribution blower A and to the air register D Although it is not mandatory it is recommended to use insulated flexib...

Страница 10: ...corative fireplace heat distribution blower will take longer to reach optimum efficiency as opposed to higher rated units which may cause the fan to cicle A Fireplace equipped with a wiring terminal 1...

Страница 11: ...stribution blower and from the fireplace terminal to the PC board see step 5 Then install the assembly in the PC board housing as shown in Figure 2 Figure 2 3 Secure the PC board assembly to the outsi...

Страница 12: ...FANHOT in the PC board and on L at the heat distribution blower terminal Connect the green or nude lead on FANFR in the PC board and on GROUND at the heat distribution blower terminal see Figure 5 In...

Страница 13: ...13 Figure 5 Figure 6...

Страница 14: ...1 Determine a location on the side of your fireplace where you can drill a hole to run your electrical wiring and in close proximity of any electrical devise if any 2 Wire the PC board see step 5 then...

Страница 15: ...15 3 Secure the PC board assembly to the PC board bracket see Figure 6 Figure 6 4 Secure the PC board bracket to the floor of the fireplace frame see Figure 7 Figure 7...

Страница 16: ...in the PC board and on L at the heat distribution blower terminal Connect the green or nude lead on FANFR in the PC board and on GROUND at the heat distribution blower terminal see Figure 9 In the ev...

Страница 17: ...17 Figure 9 Figure 10...

Страница 18: ...etermine at what temperature in Fahrenheit the heat distribution blower will switch from low speed to high speed Options for Setpoint 2 are 175 F 190 F or 205 F Thermostat allows choosing the Cool or...

Страница 19: ...19 Notes...

Страница 20: ...20 Stove Builder International inc 250 rue de Copenhague Saint Augustin de Desmaures Quebec Canada G3A 2H3...