Saxby 78654 Скачать руководство пользователя страница 1

Track 1m/2m/3m

 

78654, 78655, 78656, 78657, 78658, 78659, 78660, 78661,78662

Instruction leaflet

Care and Safety

 We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could

 damage the finish.

 For your safety, always switch off the supply before cleaning.

Iss .5 18/03/2019

WWW.saxbylighting.com

Saxby lighting. BH23 3PE

Wiring

Connection 

Max total length of track/ load  

 Undo the screw and remove the cover from the live end. Push out the desired cable access point.

Indentify the correct cable from the supply and pull through.

Refit the cover onto the live end taking care not to trap the cable.

Connect the supply wires to the terminal block, opposite the corresponding wires from the fitting. 

The central connector can also be wired in this way.

N

L

N

L

Supply

Check that.....

You have correctly identified the wires.

The connections are tight.
No loose strands have been left out of 

the connection block.

The track accessories are provided with earth connection

points on both sides.

When offering the accessory to the track, verify which

tab needs to be removed. (See left hand diagram).

To remove the tab, grasp firmly with a pair of pliers

and lever back. The tab should snap cleanly off. 

(See right hand diagram).

Locate the accessory in the track and push home.

Our recommendation would be to remove a secition 

of material from the end of the track that is opposite 

to that of the live feed. This would ensure a perfect 

connection and trouble free operation. Always ensure 

that the locking screw is tightened.

Locate the product in the track with the connections

in the slot.

End view of track

Earth

Conductor

Remove One

or Other Tab

Marked in Grey

Remaining Earth tab needs 

to be inserted into Earth 

conductor to ensure Earth 

continuity.

Item 

Model    

Component for 

track system

 

Max total

 load weight

   Max total 

length of track

Max. 15kg

50M

78654 / 78655 / 78656
78657 / 78658 / 78659
78660 / 78661 / 78662

1
2
3

220-240VAC,16A

Rating input

220-240VAC,16A
220-240VAC,16A

1 meter 3 wire track
2 meter 3 wire track
3 meter 3 wire track

Max. 20kg  
Max. 30kg

Отзывы: