Iss.4 18012016
We recommend cleaning with a soft dry cloth.
Do not use solvents or abrasive cleaners as these could damage the finish.
Waste electrical products should not be disposed of with household waste. Please recycle where
facilities exist. Check with your Local Authority or retailer for recycling advice.
Live Voltages may be present in this unit even when turned of or when completely disconnected.
For your safety, always switch off the supply before changing lightbulbs, or cleaning.
This system contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.
Saxby Lighting Ltd. BH23 3PE
Care and Cleaning
Recycling Advice
Safety Information
Battery Replacement
If after routine operation check, the lamp does not remain lit for the three hour period, a new battery pack may be
required.
1. Switch off the electricity at the mains.
2. Allow batteries to fully discharge then reconnect to supply and allow to charge for 24 hours.
3. Test again for 3 hours, if light does not remain lit change the battery pack as follows:
4. Undo the two screws on end of the diffuser and lift off. Undo the two screws holding the gear tray in place
and set aside.
5. Unplug the battery lead from the circuit board. Cut the cable ties and pull the battery pack away from the gear
tray.
6. Write current date on the new battery pack.
7. Fit new battery pack using self adhesive pads or similar. Refit the cable ties in position and then plug battery
pack into circuit board.
8. Close and secure gear tray and replace diffuser.
9. Restore power and allow to charge for 24 hours.
10. Perform full operation check and update test record.
Operating Instructions
1. Connect the unit to the mains (220-240V a.c.).
2. Charge the battery for at least 18 hours before first use.
3. When the unit is installed a green LED indicates that mains power is present. If this indicator is not lit there
could be a fault with the fitting or supply. The battery is not charging if the LED indicator is off.
4. The unit is always lit. Upon the power failing the unit will remain lit.. Please note that the unit does not have an
off function.
5. The battery should be re-charged and checked every three months.
6. The battery should be discharged and and the duration of the LED’s checked every six months. When the
duration is 50% the the battery must be replaced.
7. The emergency function can be tested using the button marked test on the end of the fitting. When you press
and hold the button the fitting will simulate a power cut and the fitting will switch to emergency mode.
Commisioning
1. Lift the unit up into place and fit over the ceiling bracket. Re-fit the screws.
2. Replace fuse or circuit breaker and switch on. Your light is now ready for use.
Luxway LED Exit Emergency
10550
10551