background image

www.saxbylighting.com

Instruction manual

90974, 90975

PIR SECURITY DETECTOR WALL

PIR Adjustment

Saxby Lighting. BH17 7BY

V1 16/10/2019

We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage the finish.
For your safety, always switch off the power supply before changing lightbulbs, or cleaning.

Care and Safety

Technical data

Conformity with all relevant EC Directive requirements.

The power supply is Double Insulated and does not require connection to an Earth circuit.

Waste electrical products should not be disposed of with household waste. Please recycle where facilities

exist. Check with your Local Authority or local store for recycling advice. 

This product is rated at IP44.

IP

44

This product is not suitable for dimming.

90974

90975

Supply Voltage: 240V~   

 

Detection Range: 180º

Power Frequency: 50Hz   

 

Detection Distance: Max.12m (<24ºC)

Ambient Light: <10-2000LUX (adjustable)  

Working Temperature: -20~+40ºC

Time Delay: Min.10sec±3sec  

 

Working Humidity: <93%RH

                   Max.7min±2min 

 

Power Consumption: approx 0.5W

Rated Load: Max.2000W  

 

Installation Height: 1.8-2.5m

                          1000W   

 

Detection Moving Speed: 0.6-1.5m/s 

TIME

LUX

TIME

LUX

• 

Turn the TIME knob anti-clockwise on the minimum (10s). Turn the LUX knob

    clockwise on the maximum (sun).

• 

Switch on the power, the sensor and its connected lamp will have no 

    signal at the beginning. After Warm-up 30sec, the sensor can start work. 
    If the sensor receives the induction signal, the lamp will turn on. While there 
    is no another induction signal any more, the load should stop working within
   10sec±3sec and the lamp would turn off.

• 

Turn LUX knob anti-clockwise on the minimum (moon). If the ambient light is

    more than 10LUX, the sensor would not work and the lamp stop working too. If
    the ambient light is less than 10LUX (darkness), the sensor would work. Under
    no induction signal condition, the sensor should stop working
    within 10sec±3sec.

Note: when testing in daylight, please turn LUX knob to       (SUN) position,
otherwise the sensor lamp could not work! 