background image

Surge (Floodlight) PIR

78963, 78965, 78967, 78969, 78970

Instruction leaflet

Care and Safety

 We recommend cleaning with a soft dry cloth. Do not use solvents or abrasive cleaners as these could damage 

 the finish.

 For your safety, always switch off the supply before cleaning.

Iss .2 22/11/2018

WWW.saxbylighting.com

Saxby lighting. BH23 3PE

PIR Specification

• 78963, 78965, 78967 and 78969 are fitted with PIR motion sensor. The specification is as follows:

• Turn the time dial to minimum(-), the sensitivity dial to m) and the lux dial to maximum (sun).

• To override the PIR, switch off the power to the floodlight then re-apply the power within 3 seconds.
• To return to automatic mode, switch off the power to the floodlight then re-apply the power after 10 seconds.

Dials shown in maximum positions

• Switch on the power supply electricity and but not activate the PIR sensor. 
• Wait approximately 15 seconds while the floodlight initiates 

by turning on and off.

• After the floodlight deactivates, it can be activated with motion 

in fornt of the PIR sensor.

• Adjust the time dial for the desired duration on and the sensitivity 

dial to the desired distance.

• Initial setup and testing in daylight is now complete.

If in doubt, contact a qualified electircian.

• Turn the lux dial to minimum(moon). When the ambient light 

level is at the desired level (to turn on the floodlight), 

rotate the lux dial until the floodlight turns on.

Please read in full before installation and keep for future reference take care not to over rotate the dials. 

They do not rotate through 360 for testing in daylight.

Installation Instructions

Manual Override Instructions

Optimum mounting height: 1m-3m.
Timer Function (TIME): 10±5 seconds to 8±2 minutes

Detection angle: 120˚

Detection distance (adjustable) : 8±2m( <24   )

Lux Range (LUX): 2-2000 lux
Working TemperaturePower:-10

— +45

 

You have correctly 

identified the wires.

The connections are tight.

No loose strands have 

been left out of the terminals.

Terminal block not included. Installation may require advice from a qualified person. Connect to an approved 

outdoor rated terminal block, observing the wiring diagram here:

SUPPLY

NEUTRAL

EARTH

SWITCHED LIVE

BLUE (N)

GREEN/YELLOW

BROWN (L)

LIGHT FITTING

Wiring

Check that...

 

Отзывы: