11

Älä lado kiviä vastustelineen 

sisäpuolelle.

Do not put stones inside

the heating element holder.

Kuva 4

Fig. 4

Vastuspidikkeet

Heating element separator

HEATER STONES

The main purpose of the stones in the heater unit is to store enough energy to  efficiently 

vaporize the water thrown on top of the stones to maintain correct humidity in the sauna 

room. The stones must be removed at least once a year or every 500 hours which ever 

occurs first. All stone crumbles must be removed from the heater unit and replaced with 

new ones as described in the heater manual. When placing the stones, recommended to 

use cut resistant gloves. The required amount of stones is listed in the manual provided 

(See page 22 Technical Data).

NOTE!

 

Never  use  the  heater  without  stones  as  it  may  cause  fire.  Use  only  manufacturer 

recommended SaWo-stones. Using unsuitable stones may lead to heating element damage 

and  will  void  the  warranty.    Never  use  eramic  stones  or  other  artificial  stones  of  any  type!

 

LOADING STONES INTO THE HEATER 

It is recommended that all stones should be rinsed to remove any stains or dust that can 

cause unpleasant odor during the first few times of using the heater. It is important that 

the stones are loaded carefully in a way that they do not block air circulation through the 

heater. Load the stones to the heater so that the heating elements are not visible from 

any angle. Larger stones that won’t fit between the heating elements must not be forced 

in place instead they must be completely removed. Small crumble or stone pieces smaller 

than 35mm in diameter must not be loaded into the heater because they will block the 

air circulation and will cause overheating and possible heating element damage. Load 

the stones to the heater so that the heating elements are not visible from any angle. If 

heating elements touch each others, it will significantly reduce the life span of heating 

element.

NOTE! 

Heating element damage due to overheating caused by wrong kind of stones or stones 

which were wrongly loaded into the heater is not covered by the factory warranty.

Before  the  heater  is  filled  with  stones,  electrician  should  test  that  the  heater  works. 

Testing can be done by turning on the heater for a short time without any stones and 

verifying that all heating elements are heating up.

NOTE!

Install heating element separator as shown 

in figure 4. The separator prevents heating 

elements from touching each other which 

improves the lifespan of heating elements.

 

HUOM!

 

Asenna vastuspidikkeet kuten kuvassa 4. 

Vastuspidikkeet estävät vastuksia koskemasta 
toisiinsa, joka pidentää niiden elinikää.

 

Содержание PHOENIX PNX3-45NS

Страница 1: ...for use in the USA Canada and Mexico Congratulations on your purchase of SAWO sauna heater Please read the manual carefully before using the heater Onnittelut loistavasta kiuasvalinnastanne Tutustu käyttöohjeisiin huolellisesti ennen käyttöönottoa PNX3 45NS PNX3 60NS PNX3 75NS PNX3 90NS PNX6 90NS PNX6 105NS PNX6 120NS PNX6 150NS PNX6 180NS ...

Страница 2: ...ARAN COVERING THE HEATER CAUSES FIRE HAZARD Turvaohjeet 4 Käyttäjälle 4 Asentajalle 6 Kiukaan asentaminen 8 Kiuaskivet 10 Kivien latominen kiukaaseen 10 Kytkentäkaavio 12 Sensorin sijainti NS mallit 13 Ilmanvaihto 14 Eristys 14 Saunahuoneen lämmitys 16 Saunan huolto 18 Vianetsintäkaavio 20 Tekniset tiedot 22 SISÄLLYSLUETTELO ...

Страница 3: ...For technicians 7 Heater installation 9 Heater stones 11 Loading stones into the heater 11 Electrical diagram 12 Sensor location NS MODELS 13 Air ventilation 15 Insulation 15 Heating of the sauna room 17 Sauna maintenance 19 Diagnostic table 21 Technical data 22 ...

Страница 4: ...ta ilman valvontaa Älä anna koskaan lasten leikkiä kiukaalla Älä käytä kiuasta grillinä Älä laita puita sähkökiukaalle Älä peitä kiuasta Se aiheuttaa palovaaran Älä kuivata vaatteita kiukaalla Se aiheuttaa palovaaran Älä istu kiukaalla Se on todella kuuma ja aiheuttaa palovammoja Älä käytä kloorivettä esim uima tai porealtaasta tai merivettä löylyvetenä Se tuhoaa kiukaan Kiukaan asentamisen jälkee...

Страница 5: ...nces should children be allowed to play with the device Do not use the heater as a grill Do not put wood of any kind on the electric heater Do not cover the heater It may cause a fire Do not use the heater as clothes dryer It may cause fire Never sit on the heater It is really hot and can cause serious burns Do not use chlorinated water e g From the swimming pool or jacuzzi or seawater It can dest...

Страница 6: ...va raitisilma ei vaikuta niiden toimintaan Julkisessa käytössä olevaan kiukaaseen jossa on viikkoajastin tai kauko ohjaus mahdollisuus on asennettava erillinen ovitunnistin saunan oveen Tunnistin kytkee pois päältä kaikki esiajastustoiminnot kun kiuas on valmiustilassa ja ovi avataan Ennen kiukaan asennusta tarkista valmistajan saunalle määrittelemät maksimi ja minimikoot Katso sivu 22 Varmista et...

Страница 7: ...d control panel must be mounted outside the sauna cabin If this sauna heater is used for public saunas or saunas that may be switched on by a separate remote control system the door of the sauna room must be fitted with an interlock such that the stand by mode setting for remote operation is disabled if the sauna door is opened when the stand by mode setting for remote operation is set Observe the...

Страница 8: ...uutiotilavuuksia kts sivu 24 tekniset tiedot tulee noudattaa Saunaan saa asentaa vain yhden kiukaan ellei sinulla ole erikoisohjeita kahden kiukaan asentamiseen Useimmissa maissa kiukaan kiinnittäminen lattiaan on säädetty lailla Kiuas on todella kuuma Suosittelemme asentamaan kiukaaseen suojakaiteen jolla vähennät kosketusmahdollisuuksia kuuman kiukaan kanssa Kiukaan liitäntäjohtona tulee käyttää...

Страница 9: ...ountries there is a law that requires heaters to be screwed to the floor The heater gets very hot To avoid the risk of accidental contact with the heater it is recommended that a heater guard be provided The cable used for sauna wiring must be HO7RN F type or its equivalent A certified electrician must do the installation of the heater to ensure safety and reliability Improper electrical connectio...

Страница 10: ...koska tämä johtaa lämmityselementtien ylikuumenemiseen ja niiden käyttöiän merkittävään lyhenemiseen Isokokoisia kiviä ei saa milloinkaan työntää väkisin lämmityselementtien väliin vaan tällaiset kivet on poistettava Kivet on ladottava siten että elementit eivät väänny ulos tai sisäänpäin ja elementit eivät saa koskettaa toisiaan kivien ladonnan tuloksena Alle 35 mm halkaisijaltaan olevia pienikok...

Страница 11: ...y do not block air circulation through the heater Load the stones to the heater so that the heating elements are not visible from any angle Larger stones that won t fit between the heating elements must not be forced in place instead they must be completely removed Small crumble or stone pieces smaller than 35mm in diameter must not be loaded into the heater because they will block the air circula...

Страница 12: ...G N V U W W V U N G 2 5 kW H1 2 5 kW H2 2 5 kW H3 2 5 kW H4 2 5 kW H5 2 5 kW H6 PNX6 180NS 18 0 kW Terminal 2 9 0 kw 9 0 kw Terminal 1 G N V U W W V U N G 3 0 kW H1 3 0kW H2 3 0 kW H3 3 0 kW H4 3 0 kW H5 3 0 kW H6 Note Relocate jumper when using 220 240V 1N Single Phase 220 240V 3 Delta Connection 4 5 Kw 400V 3N 50 60Hz PNX3 45NS P N G W V U 1 5 1 5 1 5 6 0 Kw 400V 3N 50 60Hz PNX3 60NS P N G 2 0 2...

Страница 13: ...perature sensor with safety fuse which prevents the heater from overheating must always be installed in the ceiling directly above the center of the Aries heater even if the control unit s manual states otherwise Installing the sensor above the Aries heater on the wall may cause over heating of the sauna heater Do not install the temperature sensor with fuse closer than 1 meter from the ventilatio...

Страница 14: ...tse kylpyhuoneessa sijaitsevaan poistoilmaventtiiliin Tällöin saunan kynnysraon on oltava vähintään 5cm ja kylpyhuoneessa olisi suotavaa olla koneellinen ilmastointi Poistoilmaventtiilin tulee olla kaksi kertaa suurempi kuin tuloilmaventtiilin ERISTYS Saunassa tulee olla asianmukaiset eristykset seinissä katossa ja ovessa Mikäli saunassa on yksi neliömetri m eristämätöntä seinäpintaa esim lasiovi ...

Страница 15: ... through a pipe from the floor going to a vent to the sauna ceiling or under the door to the washroom In this case the sill slot must be at least 5cm and it is recommended that there is mechanical ventilation in the washroom The size of the exhaust should be twice that of the inlet INSULATION The sauna must have proper insulation on the walls ceiling and door One square meter m of un insulated sur...

Страница 16: ...ytön Mikäli savua tai hajua muodostuu yhä poistu saunasta välittömästi ja toista vaiheet 1 3 uudelleen Tarkistasaunaainaennenkiukaanpäällekytkemistä etteikiukaallataisensuojaetäisyyksien sisällä ole mitään palavaa Varmista että saunan tuuletus on riittävä ja asianmukainen Teholtaan oikean kokoinen kiuas lämmittää saunahuoneen valmiiksi noin tunnissa Katso sivu 22 Saunan lämpötilan tulisi olla noin...

Страница 17: ... for the first time 4 If no smoke or odor is produced the next time the sauna heater is heated up you can start to use the sauna If smoke or odor is produced again leave the sauna cabin immediately and repeat the initial heating up process followed by ventilation Always check the sauna room before switching sauna heater on to be sure that there is no combustible things within the safety distances ...

Страница 18: ...uteet lattia katto ja seinät Älä käytä puupintojen pesuun ammoniakkia tai klooria sisältävää pesuainetta Huuhtele pesuaine pois kylmällä vedellä Tuuleta sauna hyvin Halutessasi voit käsitellä lauteet saunapinnoille tarkoitetulla suoja aineella Lue suoja aineen käyttöohjeet tarkasti pakkauksesta ennen tuotteen käyttämistä 9 9 Jos lauteet eivät puhdistu pesemällä hio lauteet kevyesti ja käsittele su...

Страница 19: ...sh Wash sauna benches ceiling floor and walls Do not use detergent which includes ammonia or chlorine Rinse surfaces with cold water and ventilate sauna room well If needed protect wood surfaces with wood treatment oil Read carefully the instructions of wood treatment oil from product packaging 9 9 If sauna benches are not getting clean after washing sand the benches with sandpaper Protect benches...

Страница 20: ... NI JA NS MALLIT Onko kiuas laitettu päälle ohjauskeskuksesta Onko tavoitelämpötila säädetty saunan lämpötilaa korkeammaksi Onko kiukaan pääkytkin päällä Ni malleissa kytkin sijaitsee kiukaan alaosassa ja Ns malleissa tehoyksikössä Ovatko kytkintaulun sulakkeet ehjät ja toiminnassa Sulakkeen laukeamisen syy tulee aina selvittää ennen kiukaan uudelleenkäyttöä Tarkista hehkuvatko kaikki vastukset ki...

Страница 21: ...igher than the temperature inside the sauna room Is the main switch ON In Ni models main switch is located at the bottom of the heater and in NS models it is on the power control Are the switchboard fuses ON and unbroken If broken find out the reason before turning ON your heater Are all heating elements glowing red when the heater is ON Is the heater s heating power enough for the sauna room See ...

Страница 22: ...OM SUPPLY SIZE OF HEATER DEPTH HEIGHT WIDTH VOLTAGE HEATING ELEMENT MIN MAX TYPE m3 mm kg HEATER MODEL STONES CONTROL FUSE SIZE OF WIRE mm2 AMP Terminal 2 T1 T2 Terminal 1 380 415V 3N 380 415V 3N 380 415V 3N 380 415V 3N 380 415V 3N 380 415V 3N 380 415V 3N 380 415V 3N 380 415V 3N 5 x 2 5 5 x 2 5 3 x 16 3 x 16 3 x 16 3 x 16 3 x 25 3 x 10 3 x 10 3 x 20 3 x 10 3 x 16 3 x 10 3 x 20 5 x 2 5 5 x 2 5 5 x ...

Страница 23: ...01 SPAREPARTS 1 Heating Element 2 Heating Element Lock w O ring screw and washer 3 Cable Holder 4 Terminal Block 7 Poles Terminal Block 5 Poles 5 Leveling Bolt 6 Grommet 7 Frame 8 Heating Element Spacer 9 Heating Element Separator VARAOSAT 1 Vastus 2 Vastuspidike O renkaalla prikalla ja ruuvilla 3 Kaapelipidike 4 Riviliitin 7 napainen Riviliitin 5 napainen 5 Säätöjalka 6 Läpivientikumi 7 Kehys 8 V...

Страница 24: ...www sawo com info sawo com Pidätämme oikeuden muutoksiin Subject to change without notice PX 4 PNX_3P_ML_FiEn0119 ...

Отзывы: