MANUAL
ENGLISH
Infrared 2.0
Congratulations on your purchase of Infrared Control Unit!
Please read the manual carefully before using the control.
Not for use in the USA, Canada and Mexico.
Страница 1: ...MANUAL ENGLISH Infrared 2 0 Congratulations on your purchase of Infrared Control Unit Please read the manual carefully before using the control Not for use in the USA Canada and Mexico ...
Страница 2: ...ructions 6 2 1 Quick Start 6 2 2 Directions of Use 7 2 2 1 Heater on 7 2 2 2 Heater off 7 2 2 3 Pre run button 7 2 2 4 Setting Mode 8 2 2 5 Fan 8 2 2 6 Cabin Light Button 8 2 2 7 Key Pad Lock 8 2 2 8 Temperature Unit Conversion 8 3 Assembly and Installation 9 3 1 IR Interface to Controller Box Connection Diagram 9 3 2 Installation of IR Interface 10 3 3 Sensor 11 3 4 Technical Diagram 12 3 5 IR Co...
Страница 3: ...epairs on the unit Use original parts only 2 Disconnect the Power Controller from the mains supply before installation or opening the lid of the power controller for repair maintenance purposes 3 Check power supply rating before installation 4 Check the correct location of the sensor in the installation section of the manual It is very important to place the temperature sensor correctly Installing...
Страница 4: ... dryer It may cause fire When installing a new IR panel switch the IR panel on for 30mins Do not stay inside the IR sauna room while performing the operation to allow some fumes and odor to dissolve that might have been produced from the package For technicians Wiring and repairs must be done by a certified electrician The sensor and IR panel should be mounted in a way so that incoming air will no...
Страница 5: ... back of the emitter as it may overheat Never throw water into the infrared panels as it may cause damage It is recommended that the infrared cabin should not be used within 24 hours after UV radiation exposure from artificial sources or sun bathing Individuals who may be at risk from hyperthermia such as individuals suffering from cardiovascular disease should seek medical advice before use of in...
Страница 6: ...2 Press arrow keys to adjust temperature 3 To change the parameter values press the Mode button 4 Now the corresponding LED is blinking faster Use the up and down arrows to change the values 5 You can move from one parameter to another by short pressing the Mode button 6 Confirm the settings by pressing the Mode button If no keys are pressed after 5 seconds the control unit will confirm the change...
Страница 7: ...changed within 5 minutes after switching the heater on 2 2 2 Heater off Turn the heater off by pressing the Power button This button will turn off all the active functions including the pre run session However the sauna room light will not be switched off Light button can be used even the heater is off Also Fan 2 2 3 Pre run button Pre run button can only be enabled in Off Mode During the pre run ...
Страница 8: ...y will confirm the change 2 2 4 Setting Mode Press the Mode button to activate setting mode It can be used to select and adjust the fan temperature and the session time Corresponding LEDs will be blinking on each selected features Change values by pressing the up and down buttons Save the settings by pressing the toggle button a high beep will confirm it If no keys are pressed within 5 seconds the...
Страница 9: ...rface is connected to a controller box where the heating panels light and fan are also connected SAWO Infrared controller consists of power controller and user interface that are connected to each other by RJ12 and a panel temperature sensor that is connected to the Power Controller by RJ12 cable 3 1 IR Interface to Controller Box Connection Diagram Fig 1 For illustrative reference only Sensor IR ...
Страница 10: ...he IR Interface 1 Mount the IR interface casing in preferred secure area on a room temperature 2 Cut the wall section according to specifications 3 Connect the Rj Cable provided from the control panel to the Controller Box 4 Insert the casing on the cut section 5 Connect the cable of the sensor to the IR Control Box OPTIONAL Interface Holder Contact your SAWO distributor NOTE When you wish to use ...
Страница 11: ...N Top view Side view Fig 4 Fig 5 Recommended location for the sensor Sensor IR Interface Air Vent 3 3 Sensor The sensor is recommended to be installed on the top center of the IR panel frame It is very important to install the sensor in a proper location for a correct temperature reading ...
Страница 12: ...N LIGHT RJ Data Cable W N R in F3 F2 RS1 RS1 RS3 K2 K4 CONTROL A IR UI V2 Primary Supply 160 mA BLACK BROWN WHITE BLUE FUS TS 1 4 2 3 TS1 Temperature Sensor with Fuse Light 60W max 100W max Fan 3 V U HTR N HTR N HTRN Heater 3 4kW max 230V 1N 50 60Hz L1 N PE Power Supply The cable must be HO7RN F type or its equivalent 3 core cable L LIGHT FAN HTR1 NN NN N HTR2 PEPE HTR3 Fig 6 ...
Страница 13: ...exceed 40 C It is protected against dripping water however it should not get in contact with water Mount the controller box on a dry location inside or outside the IR Sauna room Install the IR Controller Box on the wall in vertical direction only and at least 300 mm from the floor refer to the illustration below Power plug is supplied together with the box 3 5 IR Controller Box 3 5 1 Installation ...
Страница 14: ...ox IR Control Sensor Pull to open Unscrew 9mm Screw the box to the wall Refer to Technical Diagram for wire connections Fig 8 Fig 9 After the installation is completed connect the power cord from the controller to the circuit breaker and the IR Sauna is ready to use ...
Страница 15: ... Celcius NC 230V 1N 100W max 230V 1N 60W max Sensor Light Bulb Cabin Light Fan Fan 160mA TS2 with RJ10 Resistive load Fan without starting capacitor For electronics Fuse F1 Fuse L 104 x W 147 H 40 L 218 x W 260 H 75 350g 1 752g Temperature sensor 1 is not connected Temperature sensor 1 is short circuit Temperature fuse is defective Communication failure or main board is turned off while contactor ...
Страница 16: ...www sawo com info sawo com Subject to change without notice PX IR 2 0 Control_En0821 ...