Страница 1: ...OWNER S MANUAL To Be Retained by Owner After Installation by Authorized Savaria Dealer Part No 000703 04 m07 2011 ES 125 Inclined Platform Lift ...

Страница 2: ...ore frequently where usage environment or local jurisdiction requires As the Owner you are responsible for ensuring that regular service and inspections occur in a timely manner Refer to this manual for specifications operating instructions and maintenance of the Savaria ES 125 Inclined Platform Lift Upon completion of installation the dealer must provide you with the following information and ens...

Страница 3: ... Operating from the Landing Station Controls 9 4 SAFETY FEATURES 10 Underpan Sensors Optional 10 Flap Sensitive Switches Optional 10 Arm Position Switches Optional 10 Seat Position Switch Optional 10 Platform Position Switch Optional 10 Emergency Stop Buttons Optional 10 Manual Lowering Device 11 5 MAINTENANCE 12 Maintenance Schedule 12 Maintenance Record 13 Operator Troubleshooting 14 ...

Страница 4: ...important notes below Read this manual carefully before using the ES 125 Inclined Platform Lift To prevent accidents adhere strictly to the instructions and keep clear of moving parts at all times Follow instructions on all equipment labels at all times Replace any damaged labels immediately Ensure that only qualified personnel perform maintenance ...

Страница 5: ...5 Part No 000703 04 m07 2011 ES 125 Owner s Manual 1 DESCRIPTION Figure 1 shows the exterior components of the ES 125 Figure 1 ...

Страница 6: ...an be folded manually or there is an optional power fold platform Unit folds up to within 11 279 mm of the wall residential Access ramps Two positive action access ramps for incline or 90 degree entry Power supply 110 VAC 15A 60 Hz single phase Motor assembly 110 VAC 1 2 hp 373 W 1750 rpm gear reducer 50 1 Drive unit Standard model Steel aircraft cable 3 16 5 mm with breaking load of 4200 lb 1950 ...

Страница 7: ...s Two handles on car Options Three position manual safety arms Two position motorized safety arms Power fold platform Flush cabinet at front or back of rail Plus model Manual lowering device Motor with electromechanical brake Manually raised side flap Automatically raised side flap Safety edge on ramp Fold up seat with seat belt Post for call send station Self support posts Outdoor package 12 volt...

Страница 8: ...o the ON position to activate the operating buttons 2 Apply constant pressure on the UP DOWN switch as required to move the platform to the desired landing 3 When the lift reaches the landing release the UP DOWN switch 4 To prevent unauthorized use of the lift take the key out when the unit is not in operation 5 Pressing the Emergency Stop button optional during travel will stop the liftimmediatel...

Страница 9: ...ey switch and turn it to the ON position to activate the operating buttons 2 Apply constant pressure on the appropriate button to call the platform to the desired landing 3 When the lift reaches the landing release the switch 4 To prevent unauthorized use of the lift take the key out when the unit is not in operation 5 Pressing the Emergency Stop button optional during travel will stop the liftimm...

Страница 10: ...ches stop the platform if the arms are in an intermediate position any position other than horizontal or vertical Seat Position Switch Optional The seat position switch if equipped is located under the seat This switch ensures that the power fold platform does not fold up when the seat is down Platform Position Switch Optional The platform position switches are located on the lower part of the fra...

Страница 11: ...ce functions the same as for the public unit described below Figure 4 ES 125P unitpulled by asteelcable public model In an emergency you can move the ES 125 P manually with a crank See Figure 4 Insert the crank and turn it to move the unit toward the desired position at the landing Always be sure to remove the crank when you re done ES 125 Plus chain driven unit Figure 5 In an emergency you can mo...

Страница 12: ...ed unfolded Arm position switches optional Seat position switch optional Every 2 months Clean bus lines if equipped with grit 400 sandpaper Every 2 months Verification by technician ONLY Frequency Verify the entire suspension system Chain or steel cable Steel cable on brake assembly Connecting links or cable clips Fastening of motor and deflecting pulleys optional Every 6 months Perform a safety b...

Страница 13: ...13 Part No 000703 04 m07 2011 ES 125 Owner s Manual Maintenance Record Date Time Reason for Call Comments Dealer ...

Страница 14: ... the activated position Platform does not move in either direction Check the power supply breaker cord etc Check that the key is ON if applicable Check to see if the Emergency Stop is pushed in it should be pulled out for normal operation If the platform is at the top landing check the underpan sensor and the flap on the lower part of the lift as described above If the platform is at the bottom la...

Страница 15: ......

Страница 16: ... Lift OWNER S MANUAL Part No 000703 Copyright 2011 Savaria Corporation Elevators and Lifts www savaria com Sales 107 Alfred Kuehne Blvd Brampton Ontario L6T 4K3 Canada Tel 905 791 5555 Fax 905 791 2222 Toll Free 1 800 661 5112 ...