MW-1000™ User Guide
15
identical to the application, which run on the same
interface.
SPATMAPPsid
0x00
(Default:
0x8002)
0xEFFFFFFF # PSID that should be used when
receiving PSIDPSID Length: Valid Values
1 byte:
00 - 7F
2 bytes: 8000 – BFFF
3 bytes: C00000 – DFFFFF
4 bytes: E0000000 – EFFFFFFF
TIMPsid
0x00
(Default:
0x8003)
0xEFFFFFFF # PSID that should be used when
receiving PSIDPSID Length: Valid Values
1 byte:
00 - 7F
2 bytes: 8000 – BFFF
3 bytes: C00000 – DFFFFF
4 bytes: E0000000 - EFFFFFFF
SPATMAPBypassSecurity
0, 1
(Default: 1)
Enable/Disable Security verification bypass
SPATMAPSecurityEnabled
0, 1
(Default:1)
0 – Disable
1 – Enable
Vehicle configurations.
File-path: /etc/config/v2vi_obe.conf
VehicleWidth
0, 10.23
(Default: 2)
Vehicle width in meters.
VehicleLength
0, 40.95
(Default: 5)
Vehicle length in meters.
VehicleHeight
0, 6.35
(Default: 1.5)
Vehicle height in meters.
VehicleType
0,15
(Default: 4)
As per J2735
6.2 Advanced Configurations - Network
IP Address configuration
The IP address configuration is available in the following file:
/etc/config/network
A sample format of the file is explained below. A single IPv4 address and up to three IPv6
addresses (ipv6addr1, ipv6addr2, and ipv6addr3 options) can be specified per interface.
Loopback Configuration
:
Configuration Item
Value
Description
config interface loopback
Network name