Savant Standalone Energy Monitor Deployment Guide
Copyright 2020 Savant Systems, Inc
009-1928-01 | 200828
22 of 24
Appendix B: Energy Monitor Data Table Index
Enabled
A check indicates the row is enabled. No check indicates the row is disabled. If the row is unchecked, that row will not generate
a control interface within the Savant UI.
Circuit Description
This category describes the physical wiring to which one or more Current Transformers are attached.
A circuit must consist of at least one phase channel, and may have up to three.
Phase channels can be added or removed by only selecting a phase channel within the circuit and pressing “+” or “-” located in
the bottom left corner of the dialog. New circuits will have one phase added automatically.
Classification
Consumption: A circuit that consumes power, which is the most typical kind of circuit.
Production: Used for any circuits that add power to monitored system.
Feed: Designates that this circuit is the Main Power input from the utility company.
Image
Allows the user to select an icon to appear in the Savant Pro App for the selected load to be monitored. Available icons are
Geo-Thermal, Wind, Stove, Solar, Pool Garage, HVAC, Dish Washer, Washing Machine, None, Lighting, Hydro, Refrigerator,
Room, Water Heater, and Appliances.
Group Image
Available icons are Geo-Thermal, Wind, Stove, Solar, Pool Garage, HVAC, Dish Washer, Washing Machine, None, Lighting, Hydro,
Refrigerator, Room, Water Heater, and Appliances.
Group
Allows for grouping and categorization of circuits that will define how the end user accesses their monitoring info within the
Savant UI. Select a predefined group (same list) or select the text field to enter a custom group name. Configured groups form
the top level navigation options presented to the user.
Monitoring Device
Choose the specific physical monitoring device, such as Energy and Resource Monitor that is connected to the circuit.
Channel
Under this category select the physical port on the energy-monitoring device to which the Current Transformer for that circuit
is connected.
Size
Under this category select the capacity of the Current Transformers used for the circuit. This capacity must exactly match the
20A, 50A, 150A or other supported CT size physically clamped onto that circuit.
Voltage Source
Under this category select from the available voltage monitoring sources that correspond to the phase channels of the circuit.
For the best and most accurate monitoring results, ensure that the voltage of each phase channel is accurately measured as
close to the trunk as possible, and that every circuit phase channel is correctly matched to its corresponding voltage sensor.
External Voltage Transformer sensors will provide more accurate voltage and power reporting, but must be physically
connected to the correct phase and each phase channel must have the correct voltage sensor selected here.
Parent Circuit
Use this category when using a current transformer on the Main Power Feed, so that the energy reading from this device does
not double-report on the energy consumption total.
Import
Cancel
Export
Done
?
Enabled Circuit Description
Classification
Group Image
Monitoring Device Channel Size Voltage Source Parent Circuit Control Savant Zone
Group
Image
Production Type