This guide describes the process for installing, configuring, and adding a Savant Energy Monitor to a RacePoint Blueprint™ configuration. Savant Energy Monitors 

are connected to a home’s existing electrical panel using clip-on current transformers, and to the Savant Host via the local network.  They allow the user to 

monitor all aspects of energy usage including heating, appliances, lighting, and more. Savant Energy Monitoring can provide data on the home’s overall energy 

use and production that is viewable any time - locally or remotely.

 

IMPORTANT!

 This guide focuses on deploying a Savant Energy Monitor for use in the Savant Pro App.

Products supported by this guide include:

 

SmartEnergy Monitor [SEM-1024]

 

Savant Standalone Energy Monitor [SEM-2015]

Содержание SmartEnergy SEM-1024

Страница 1: ...Monitors are connected to a home s existing electrical panel using clip on current transformers and to the Savant Host via the local network They allow the user to monitor all aspects of energy usage...

Страница 2: ...Three Phase Consumption Only 6 2 3 Single Phase with Power Generation 7 3 Installation 8 3 1 Flat Surface 8 SEM 2015 8 SEM 1024 8 3 2 Din Rail 9 3 3 Voltage Transformers 10 3 4 Current Transformers 11...

Страница 3: ...device 9 If the provided plug does not fit the desired outlet contact a licensed electrician to replace the obsolete outlet 10 Protect any power cord from being walked on pinched strained or otherwise...

Страница 4: ...page can be used as a checklist to mark progress as steps are completed Review product specifications and connection details See the device s Quick Reference Guide on the Savant Customer Community Ins...

Страница 5: ...eployment Guide Copyright 2020 Savant Systems Inc 009 1928 01 200828 5 of 24 2 System Diagrams 2 1 Single Phase Consumption Only Typical 200 Amp Service Power from Utility Current Transformers Voltage...

Страница 6: ...ant Standalone Energy Monitor Deployment Guide Copyright 2020 Savant Systems Inc 009 1928 01 200828 6 of 24 2 2 Three Phase Consumption Only Current Transformers Voltage Transformers Main Branch Monit...

Страница 7: ...ds true for Wind Geothermal or Auxiliary Generators Power from Utility Current Transformers Solar Voltage Transformers Main Branch Monitors Inverter s TIP The diagram above shows one example of how to...

Страница 8: ...ilable wall anchors can be used SEM 1024 Mounts to a wall or similar surface using the included chassis mounted side brackets and supplied M3 x 8mm flat head screws Mount chassis in a place that is dr...

Страница 9: ...ed universal din rail clip To install using a Din Rail do the following 1 Remove the screws holding the mounting plate on the bottom of the unit 1 2 Remove the mounting plate 3 Align the Universal Din...

Страница 10: ...uit is run into the box 1 Switch the circuit breaker to the circuit that the SEM VT01 is being added to 2 Using diagram to the right make high voltage connections 3 Screw the SEM VT01 into the electri...

Страница 11: ...e proper polarity install the 20 and 50A current transformers with arrows pointing in the direction of current flow towards the load C Route the wire through a cable clamp on the side of the panel and...

Страница 12: ...ct the Energy Monitor and drag into a Global Zone 4 Name the device 5 Place the Energy Monitor in the Layout window 6 Select the Energy Monitor 7 Open Inspector 8 Enter UID Components All Control Type...

Страница 13: ...s Energy Monitor 2 Click the Add for SEM2015 Add for SEM1024 2 3 3 Select the Energy Monitor to be used 4 Double click on the Circuit Description Enabled Circuit Description Classification Group Image...

Страница 14: ...n Group Image Monitoring Device Channel Size Voltage Source Parent Circuit Control Savant Zone Group Image Production Type Main Power None Feed SEM2015 1 None Choose Utiliy Ro Phase 1 Channel 250 A Vo...

Страница 15: ...e house From an open Blueprint configuration do the following 1 Go to Tools Settings Energy Monitor 2 Click the Add for SEM2015 Add for SEM1024 2 3 3 Select the Energy Monitor to be used 4 Double clic...

Страница 16: ...n Family Room Room SEM2015 10 None Choose Family R Phase 1 Channel Consumption 9 Phase 2 Channel Consumption Only Main Feed Key Loads This example shows the main power feed and key loads being monitor...

Страница 17: ...Consumption Consumption Production Family Room Room SEM2015 10 None Choose Family R Phase 1 Channel Consumption 9 Phase 2 Channel Solar Auxiliary Generator The example below shows a completed configu...

Страница 18: ...Phase 1 Channel Dishwasher Appliances SEM2015 01 6 None Choose Kitchen Phase 1 Channel A C hvac SEM2015 01 7 None Choose Utiliy Ro Phase 1 Channel Work Shop None SEM2015 02 1 None Choose Work Sh Phase...

Страница 19: ...he Current rating of the current transformer 7 Select the circuits Classification 8 Repeat steps 4 though 7 for each current transformer is use 9 Click Deploy Config HELPFUL INFO Inv This column stand...

Страница 20: ...al Voltage sensor for use in conjunction with Savant Energy Monitors SEM 020A5 SEM 020A5 is a 5 pack of 20 Amp split core clip on current transformers SEM 050A5 SEM 050A5 is a 5 pack of 50 Amp split c...

Страница 21: ...tems Inc 009 1928 01 200828 21 of 24 SKU Description Image SEM 250A1 SEM 250A1 is a 250 Amp split core clip on current transformer SEM 400A1 SEM 400A1 is a 400 Amp split core clip on current transform...

Страница 22: ...he end user accesses their monitoring info within the Savant UI Select a predefined group same list or select the text field to enter a custom group name Configured groups form the top level navigatio...

Страница 23: ...fication Options include Generator Solar or Battery Clicking this box will do the following If a circuit level row is selected or there is no selection a new circuit will be added If a phase channel i...

Страница 24: ...l rights reserved Savant Savant App TrueImage Savant Host Now You Can RacePoint Blueprint Single App Home TrueCommand TrueControl and the Savant logo are trademarks of Savant Systems Inc AirPlay Apple...