Stand Alone Energy Monitor | 009-1836-02
45 Perseverance Way, Hyannis, MA 02601
Copyright 2020 Savant Systems, Inc | 200728
1 of 4
Savant® Stand Alone Energy Monitor (SEM-2015)
Quick Reference Guide
Box Contents
(1) Stand Alone Energy Monitor
(1) Install Kit (075-0227-xx)
(1) Universal Din Rail Mounting Clip (015-0255-xx)
(1) Power Supply (025-0192-xx)
(1) 6-Pin Screw Down Connector (028-0664-xx)
(15) 2-Pin Screw Down Connector (028-0884-xx)
(4) #6x1/4 PH Flat Screws (039-0143-xx)
(1) Product Regulatory Insert (009-1950-xx)
Accessories (sold separately)
–
SEM-VT01 - SmartEnergy Voltage Sensor
–
Split Core Current Transformers (Clamp-on) with 8ft leads.
–
SEM-020A5
20 Amps
5 Pack
–
SEM-050A5
50 Amps
5 Pack
–
SEM-150A1
150 Amps
1 Pack
–
SEM-150A5
150 Amps
5 Pack
–
SEM-250A1
250 Amps
1 Pack
–
SEM-400A1
400 Amps
1 Pack
–
SEM-600A1
600 Amps
1 Pack
Specifications
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 90% Relative Humidity (non-condensing)
Dimensions and Weight
Height
9.5 in (24.13 cm)
Width
9.7 in (24.64 cm)
Depth
3.3 in (8.38 cm)
Weight
Shipping: 2.65 lb (1.2 kg)
Power
Input Power
5V DC
Nominal Power
3W (10W max)
Regulatory
Safety and
Emissions
FCC Part 15B
CE Mark
RoHS
Compliant
Minimum Support Requirements
Software
Release
da Vinci 9.1
Important Information
–
All wiring in the United States must be installed in accordance with
the latest adopted edition of the National Electrical Code (ANSI/
NFPA 70, NEC).
–
All wiring in Canada must be installed in accordance with the latest
adopted edition of the Canadian Electrical Code (CSA C222.2 CEC,
Part 1) and any provincial or local requirements.
–
Savant’s largest Current Transformer supports wire up to 500 MCM
(this with jacket is just under 1 inch).
TIP!
MCM refers to circular mils and is often used for wire larger
than the AWG measurement accommodates.
–
Maximum length for leads on each current transformer should not
exceed 8 feet. Longer lengths will cause inaccurate readings.
–
If required, the leads on the current transformers can be shortened.
Left Side Panel
5 VDC
Power Input
- Connect the supplied power
adapter between the 5V DC port and a surge
protected (120-240V AC, 50/60 Hz) outlet.
Ethernet
8-Pin RJ 45 port. 10/100/1000 BaseT auto-
negotiating port with link activity LEDs
Status
Blinking Red
- Embedded firmware is running
but has not received an IP Address.
Solid Green
- Connected to the local network
and communicating with the Savant System
Host.
Reset
Press and release to perform a hard reset. Status
LED will illuminate while button is pressed.
Device Reset
:
1. Disconnect power.
2. Reconnect power wile holding the reset
button for 40 seconds.
Device will reboot clearing its configuration
and resetting its password.
(Ground)
Chassis Ground (optional)
Right Side Panel
B
A
N/A
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
C
VT Connections
Voltage Transformer
- (3) Voltage sensor input
ports. Input port for the SEM-VT01 voltage
sensor.
CT Connections
Current Transformer
- (15) Input ports for each
Current Transformer installed in the system.
Mounting
The SEM-2015 can be mounted to either a wall or similar using the pre-
installed Mounting Bracket and the included #6x1/4 PH Flat Screws.
Also the device can be mounted to a Universal Din Rail by removing
the Mounting Bracket and attaching the included Universal Din Rail
Clip on the bottom of the device. For more information on mounting
see the Standalone Energy Monitor Deployment Guide on the