Multi-Gang Installations
When combining multiple keypads into a multi-ganged box, derating is required per table below. Remove the outside tabs from one
or both sides of each device so they all fi t into the electrical switch box. Below are examples of 2, 3 and 4-gang scenarios.
–
Tabs are removed from both sides of the inside gang devices.
–
Tabs are NOT removed from outside edges of the devices at the end of each gang.
Derating Table
Device
Load Type
1-Gang
2-Gang
3-Gang
4-Gang
Adaptive Dimmer
Incandescent
600W
550W
500W
500W
CFL/LED
150W
150W
150W
150W
Magnetic Low Voltage
600VA (450W)
550VA (400W)
500VA (375W)
500VA (375W)
Electronic Low Voltage
450W
400W
375W
375W
Wiring Diagrams
The diagrams below display how to wire the Metropolitan style keypad. Any unused wires must have the bare wire portion (stripped
end) cut o
ff
and the wire must be capped with a wire nut.
Single Dimmer Installation Example
No Neutral Dimmer Installation Example
WARNINGS
:
–
Using the dimmer in a No Neutral confi guration with loads other than incandescent is not supported.
–
In a No Neutral confi guration, if the type of load installed is not supported by the dimmer, the dimmer will not supply power
to the load and the six dimmer LEDs on the front of the dimmer will blink rapidly.
From
Power
Cap if
Unused
FROM
POWER
Black
Tape
Black
Tape
Cap if
Unused
UP
120V 60Hz
UP
120V 60Hz
UP
UP
UP
120V 60Hz
120V 60Hz
120V 60Hz
UP
120V 60Hz
UP
UP
UP
120V 60Hz
120V 60Hz
120V 60Hz
Metropolitan Wireless Keypads and Dimmers
1 of 4
Copyright © 2018 Savant Systems, LLC
009-1436-04 | 181212
Metropolitan Wireless Keypads and Dimmers
Quick Reference Guide
The Metropolitan wireless keypads and Dimmers are specifi cally designed to function within a Savant Control system to switch
most lighting loads. This includes incandescent, magnetic and electronic low voltage, dimmable CFL, and dimmable LED lamps.
The Savant wireless keypads replace any standard 120V AC light switch or dimmer and can be wired into either a standard or
no neutral confi guration. With the addition of the Savant Auxiliary Control, these keypads can accommodate most 3-way wiring
designs for multi-location control.
Finally, these Keypads and Dimmers utilizes the local 802.11 b/g/n wireless network to allow it to be added to the Savant Pro System
for complete control of lighting as well as other switching and dimming functions.
Products
Adaptive Dimming
Metropolitan Wireless Keypad (WIK-xxx104)
Metropolitan Wireless Dimmer (WID-xxx102)
Box Contents
(1) Keypad/Dimmer without faceplate
(2) Mounting Screws
(5) Wire Nuts
(1) Quick Reference Guide (this document)
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 90% Relative Humidity
(non-condensing)
Location
Indoor Use Only
Pollution
Degree 2
Specifi cations
Dimensions
Height
4.13in (10.49cm) Shipping 7.0in (17.78cm)
Width
2.38in (6.05cm) Shipping 4.5in (11.43cm)
Depth
2.08in (5.28cm) Shipping 3.0in (7.62cm)
Weight
Shipping 0.60lb (0.272kg)
Recommended Back Box Depth
All Metropolitan Dimmers and switches require a standard U.S.
electrical back box.
–
Recommended - 3.5 in (8.89 cm) deep
–
Minimum 2.25 in (5.72 cm) deep
–
Type 1 enclosure for control
Power
Input
120V AC at 60 Hz
Power:
Load (Max)
600W 5A @ 120V AC (See
Derating Table
)
Supported Load Types
Standard
Confi guration
Incandescent, Electronic/Magnetic Low
Voltage, Dimmable CFL, Dimmable LED
No Neutral
Confi guration
Incandescent only
(minimum load = 25Watts)
Standards
Wireless
802.11 b/g/n 2.4 GHz (only)
Security
WPA™, WPA2™, WPA1™ +WPA2™, WEP
Regulatory
Safety and
Emissions
FCC Part 15 | UL
For more details, see the Regulatory and
Safety insert.
Contains FCC
ID:
TLZ-CU277B
Contains IC:
6100A-CU277B
RoHS
Compliant
Minimum Supported Release
da Vinci Blueprint 8.2
WARNING!
Using a keypad in No Neutral confi guration
with loads other than incandescent is not supported.
Installation
Operating
Control
Type 1.B action
Software Class A
Additional Documentation
Installation and Calibration (009-1459-xx)
Programming Guide (009-1461-xx)
Provisioning Guide (009-1460-xx)
Front Assembly Conversion (009-1376-xx)
For Product Info