Multi-Gang Installations

When combining multiple keypads into a multi-ganged box, derating is required per table below. Remove the outside tabs from one 

or both sides of each device so they all fi t into the electrical switch box. Below are examples of 2, 3 and 4-gang scenarios.

 

Tabs are removed from both sides of the inside gang devices.

 

Tabs are NOT removed from outside edges of the devices at the end of each gang.

 Derating Table

Device

Load Type

1-Gang

2-Gang

3-Gang

4-Gang

Adaptive Dimmer

Incandescent

600W

550W

500W

500W

CFL/LED

150W

150W

150W

150W

Magnetic Low Voltage

600VA (450W)

550VA (400W)

500VA (375W)

500VA (375W)

Electronic Low Voltage

450W

400W

375W

375W

Wiring Diagrams

The diagrams below display how to wire the Metropolitan style keypad. Any unused wires must have the bare wire portion (stripped 

end) cut o

ff

  and the wire must be capped with a wire nut.

Single Dimmer Installation Example

No Neutral Dimmer Installation Example

 WARNINGS

:

 

Using the dimmer in a No Neutral confi guration with loads other than incandescent is not supported.

 

In a No Neutral confi guration, if the type of load installed is not supported by the dimmer, the dimmer will not supply power 

to the load and the six dimmer LEDs on the front of the dimmer will blink rapidly.

From 

Power

Cap if 

Unused

FROM

POWER

Black 

Tape

Black

Tape

Cap if 

Unused

UP

120V 60Hz

UP

120V 60Hz

UP

UP

UP

120V 60Hz

120V 60Hz

120V 60Hz

UP

120V 60Hz

UP

UP

UP

120V 60Hz

120V 60Hz

120V 60Hz

Metropolitan Wireless Keypads and Dimmers

1     of     4

Copyright © 2018 Savant Systems, LLC

009-1436-04  |  181212

Metropolitan Wireless Keypads and Dimmers

Quick Reference Guide

The Metropolitan wireless keypads and Dimmers are specifi cally designed to function within a Savant Control system to switch 

most lighting loads. This includes incandescent, magnetic and electronic low voltage, dimmable CFL, and dimmable LED lamps.
The Savant wireless keypads replace any standard 120V AC light switch or dimmer and can be wired into either a standard or 

no neutral confi guration. With the addition of the Savant Auxiliary Control, these keypads can accommodate most 3-way wiring 

designs for multi-location control.
Finally, these Keypads and Dimmers utilizes the local 802.11 b/g/n wireless network to allow it to be added to the Savant Pro System 

for complete control of lighting as well as other switching and dimming functions.

Products

Adaptive Dimming

Metropolitan Wireless Keypad (WIK-xxx104)
Metropolitan Wireless Dimmer (WID-xxx102)

Box Contents

(1)  Keypad/Dimmer without faceplate
(2)  Mounting Screws
(5)  Wire Nuts
(1)  Quick Reference Guide (this document)

Environmental

Temperature

32° to 104° F (0° to 40° C)

Humidity

10% to 90% Relative Humidity

(non-condensing)

Location

Indoor Use Only

Pollution

Degree 2

Specifi cations

Dimensions

Height

4.13in (10.49cm) Shipping 7.0in (17.78cm)

Width

2.38in (6.05cm) Shipping 4.5in (11.43cm)

Depth

2.08in (5.28cm) Shipping 3.0in (7.62cm)

Weight

Shipping 0.60lb (0.272kg)

Recommended Back Box Depth

All Metropolitan Dimmers and switches require a standard U.S. 

electrical back box.

 

Recommended - 3.5 in (8.89 cm) deep

 

Minimum 2.25 in (5.72 cm) deep

 

Type 1 enclosure for control

Power

Input

120V AC at 60 Hz

Power:

Load (Max)

600W 5A @ 120V AC (See 

Derating Table

)

Supported Load Types

Standard 

Confi guration

Incandescent, Electronic/Magnetic Low 

Voltage, Dimmable CFL, Dimmable LED

No Neutral 

Confi guration

Incandescent only

(minimum load = 25Watts)

Standards

Wireless

802.11 b/g/n 2.4 GHz (only)

Security

WPA™, WPA2™, WPA1™ +WPA2™, WEP

Regulatory

Safety and 

Emissions

FCC Part 15 | UL

For more details, see the Regulatory and 

Safety insert.

Contains FCC 

ID:

TLZ-CU277B

Contains IC:

6100A-CU277B

RoHS

Compliant

Minimum Supported Release

da Vinci Blueprint 8.2

 WARNING!

 Using a keypad in No Neutral confi guration 

with loads other than incandescent is not supported.

Installation

Operating 

Control

Type 1.B action

Software Class A

Additional Documentation

Installation and Calibration (009-1459-xx)
Programming Guide (009-1461-xx)
Provisioning Guide (009-1460-xx)
Front Assembly Conversion (009-1376-xx)

For Product Info

Отзывы: