ITP-E8000x | 009-1522-04 | 191009
1 of 2
45 Perseverance Way, Hyannis, MA 02601
Copyright © 2019 Savant Systems, LLC
Savant® Touch 8 Inch Control Screen (ITP-E8000x-xx) Quick Reference Guide
Box Contents
(1) Savant 8.0 inch In-Wall Touch Screen (ITP-E8000x-xx)
(1) Installation Kit (075-0203-xx)
(1) Installation Template (009-1561-xx)
(1) Mounting Bracket (For standard 2-gang electrical box)
(4) Mounting Bracket Screws (6/32 x 1 in.)
(1) Savant Touch 8 Inch Control Screen Quick Reference Guide
(009-1522-xx)
Environmental
Temperature
32° to 104° F (0° to 40° C)
Humidity
10% to 90% Relative Humidity (non-condensing)
Dimensions
Viewing Image
(IPS)
8.0 in (203.0mm)
Resolution
1280 X 800 | 16.7M colors
Height
5.84 in (148.4 mm)
Width
8.80 in (223.5 mm)
Depth (overall)
1.43 in (36.3 mm)
Depth
(mounting)
0.62 in (15.8 mm)
Weight
0.95 lb (0.44 kg)
Power
PoE
802.3af compliant
Power
consumption
Average
5.14W
Maximum
6.76W
Minimum Supported Release
Savant OS
da Vinci 8.10.1
Regulatory
Safety and
Emissions
CE
FCC Part 15
WEEE
RoHS
Compliant
Specifications
Network Requirements
Savant requires the use of business class/commercial grade network
equipment throughout the network to ensure the reliability of commu-
nication between devices. These higher quality components also allow
for more accurate troubleshooting when needed.
Connect all Savant devices to the same local area network (LAN) or
subnet as the Host. Savant recommends not implementing any type of
traffic or packet shaping in your network topology for Savant devices,
as this may interfere with performance.
Network Changes
If the IP addressing range has changed for the local network, Savant
recommends rebooting the device via the Settings menu to refresh the
network connection and ensure optimal communication:
Navigate from the Home Screen
Rooms
> Select Location >
Settings
>
Reboot
A
B
C
D
E
F
G
H
I
J
Front Panel
Rear Panel
D
Proximity
Sensor
Mounted on the front of the panel, the proximity
sensor will wake up the screen when motion is
detected in the area.
Micro USB
Not Used
Embedded
Speaker
Primarily used for entry service intercom fea-
ture.
Mounting
Slots
Align the mounting fram hooks and press down
to seat. Refer to the
section on Page
2.
Alternative
Power Input
Not Used
Link LED
Solid Orange - Link is established.
Off – No link established
Link Activity
LED
Green Blinking - Indicates data activity.
Off – No Activity
Ethernet
8-pin RJ-45 port:
10/100/1000 Base-T auto-negotiating port with
link and activity LEDs
Captive
Screws
Used to secure touch panel to bracket after
mounting frame hooks have been seated. Refer
to the
section on page 2 for details.
Embedded
Microphone
Primarily used for entry service intercom fea-
ture.
B
C
D
E
F
H
I
J
G
A
Network Configuration
To ensure that the IP address will not change due to a power outage,
a static IP address or DHCP reservation should be configured. Savant
recommends using DHCP reservation within the router. By using this
method, IP addresses for all devices can be managed from a single UI
avoiding the need to access devices individually.
Setting DHCP reservation varies from router to router. Refer to the
documentation for the router to configure DHCP reservation.