Sauter GmbH

 

Ziegelei 1 
D-72336 Balingen 
e-mail: [email protected] 

Phone : +49-[0]7433- 9933-0 
Fax: +49-[0]7433-9933-149 
Internet: www.sauter.eu 

 
 
 
 

Instruction Manual Ultrasonic Material 
Thickness Gauge 

 
 
 

SAUTER TB-US, TB-US-red 

Version 2.0 
04/2020 
GB 
 

 

TB_US-BA-e-2020 

 PROFESSIONAL MEASURING 

Содержание TB-US

Страница 1: ...gen e mail info kern sohn com Phone 49 0 7433 9933 0 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction Manual Ultrasonic Material Thickness Gauge SAUTER TB US TB US red Version 2 0 04 2020 GB TB_US BA e 2020 PROFESSIONAL MEASURING ...

Страница 2: ... SAUTER We hope you will enjoy your quality measuring device with its wide range of functions For questions wishes or suggestions we are at your disposal Table of contents 1 Functions 3 2 Technical data 3 3 Description of the control panel 4 4 Material selection 4 5 Calibration Adjustment 6 6 Measuring procedure 6 7 Measuring with adjustment of the ultrasonic speed 7 8 Battery replacement 8 ...

Страница 3: ...ickness of many materials e g steel cast iron aluminium copper brass zinc quartz glass polyethylene PVC grey cast iron nodular cast iron Automatic shutdown function to maintain power 2 Technical data TB US TB US red Display 4 digits 10mm LCD display Measuring range 1 5 200mm 45 steel Resolution 0 1mm 0 001 inch Measurement uncertainty 0 5 n 0 1 Sound velocity 500 9000m s Ambient temperature 0 50 C...

Страница 4: ...able below stands for the material to be measured xxxx is a 4 digit number indicating the sound velocity for the material selected by the user 4 1 Sensor plug 4 2 Display 4 3 mm inch Button 4 4 On and Off Button 4 5 Material selection button 4 6 Plus key 4 7 Ultrasonic measuring head 4 8 Calibration key adjustment 4 9 Minus key 4 10 Battery compartment 4 11 Display Measuring process is running 4 1...

Страница 5: ...1 or when the minus key 3 9 is pressed it displays cd01 The 4 digit number represents the last sound velocity defined by the user By changing the speed of sound varying material properties can be compensated 5 Once the material code has been selected and stored it is stored in the instrument memory As long as no change is made the meter always uses this material code 6 To enter the material code s...

Страница 6: ...ibration adjustment is now completed and is automatically stored in the device 7 Measuring procedure 1 The power button 4 4 is pressed to switch on the unit 2 The mm inch key 4 3 is pressed to select the correct measuring unit 3 The measuring head 4 7 is placed on the material surface to be measured provided that the material code has been selected correctly Make sure that the Measuring process in...

Страница 7: ...splay the material thickness can now be read provided that the coupling is good If the sound velocity of a certain material is known it is easy to measure the material thickness 3 Layer thickness material thickness measurement at unknown sound velocity Take a material sample with known material thickness and adjust the speed of sound as described in 2 and 3 is repeated until the measured value cor...

Страница 8: ...y cover is stripped off the meter and the batteries are removed 3 The batteries are inserted by observing the polarity when inserting them 4 If the device is not used for a longer period of time the batteries should be removed Note To view the CE declaration please click on the following link https www kern sohn com shop de DOWNLOADS ...