Instruction Manual 
Digital Lightmeter 

 

 

 

 

SAUTER SP 200K 

Version 1.1 
01/2018

 

GB 

 

 

 

SP_200K-BA-e-1811 

 

 

Содержание SP 200K

Страница 1: ... Ziegelei 1 D 72336 Balingen E Mail info sauter eu Tel 49 0 7433 9933 199 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction Manual Digital Lightmeter SAUTER SP 200K Version 1 1 01 2018 GB SP_200K BA e 1811 ...

Страница 2: ...se Please read the following instructions care fully and always keep this manual within easy reach We hope you are pleased with your high quality Light Meter If you have any queries wishes or helpful suggestions do not hesitate to call our service number Table of contents 1 Instruction 3 2 Features 3 3 Specifications 3 4 Name of parts and positions 4 5 Spectral sensitivity characteristics 5 6 Oper...

Страница 3: ...turing peak values Unit and numeral display for easy reading Automatic zeroing The Correction factor doesn t have to be manually calculated for non standard light sources Short rise and fall times Suitable for LED light 3 Specifications Display 3 digit LCD Measuring range 200 2 000 20 000 200 000 Lux 20 000 Lux range reading x 10 200 000 Lux range reading x 100 20 200 2 000 20 000 FC 20 000 FC ran...

Страница 4: ...mperature 10 C to 50 C 14 F to 122 F Storage Temperature 0 to 80 RH Power Source One 9V battery 6F22 Battery life typically 200h Dimensions 185mmx68mmx38mm Weight 130g Accessories Carrying bag instruction manual battery 4 Name of parts and positions 1 LCD Display 3 digits with a maximum reading of 1999 2 Power key the power key turns the light meter ON or OFF ...

Страница 5: ...c curve V as described in the following chart below 6 Operation instructions 1 Power key The power key has to be pressed to turn the light meter ON or OFF 2 Selection of the Lux FC scale The range selection switch has to be set to the desired Lux FC range 3 The photo detector cap has to be removed and it has to be faced to the light source in a horizontal position 4 The illuminance nominal value c...

Страница 6: ...uld be cleaned with a damp cloth from time to time and if necessary 2 The instrument may not be stored when temperature or humidity is exces sively high 3 The calibration interval for the photo detector will vary according to operational conditions but generally the sensitivity decreases in direct proportion to the product of luminous intensity by the operational time In order to maintain the basi...

Страница 7: ...e area 150 200 Shop window packing counter 750 1500 Front sector of a shop window 1500 3000 Note If the protective cap is placed on the photoelectric sensor the reading shows 0 00 on a continuous basis if this is the case do not manipulate the potenti ometer at the back of the housing Annotation To have a look at the CE Declaration of Conformity please click onto the following link https www kern ...