Instruction Manual 
Digital Lightmeter 
 

 

 

 

SAUTER SO 200K 

Version 1.3 
08/2017

 

GB 

 

 

 

SO_200K-BA-e1713 

 

 

   

PROFESSIONAL MEASURING 

Содержание SO 200K

Страница 1: ... D 72336 Balingen E Mail info sauter eu Tel 49 0 7433 9933 199 Fax 49 0 7433 9933 149 Internet www sauter eu Instruction Manual Digital Lightmeter SAUTER SO 200K Version 1 3 08 2017 GB SO_200K BA e1713 PROFESSIONAL MEASURING ...

Страница 2: ...owing in structions carefully and always keep this manual within easy reach We hope you are pleased with your high quality Light Meter If you have any queries wishes or helpful suggestions do not hesitate to call our service number Summarize 1 Instruction 3 2 Features 3 3 Specifications 3 4 Name of parts and positions 4 5 Spectral sensitivity characteristics 5 6 Operation instructions 5 7 Battery ...

Страница 3: ...ding Automatic zeroing Meter corrected for Luminous Efficiency function The Correction factor doesn t have to be manually calculated for non standard light sources Short rise and fall times 3 Specifications Display 3 digit LCD Measuring range 200 2 000 20 000 200 000 Lux 20 000 Lux range reading x 10 200 000 Lux range reading x 100 20 200 2 000 20 000 FC 20 000 FC range reading x 10 1 FC 10 76 Lux...

Страница 4: ...of 1999 2 Power key the power key turns the light meter ON or OFF 3 Data Peak button the PEAK key has to be pressed again to clear the peak re cording mode 4 Range button the range button has to be pressed to change the ranges of 200Lux 20FC 2 000Lux 200FC 20 000Lux 2 000FC 200 000Lux 20 000FC circu larly 5 Data Hold button If the HOLD key is pressed the HOLD mode is selected When this mode is bei...

Страница 5: ...s to be pressed to select the HOLD mode the light meter will stop all further measurements If the HOLD button is pressed again this operation will be cancelled and the light me ter will return to normal operation 7 Data PEAK mode The PEAK key has to be pressed to select the PEAK mode If this item is selected the light meter stops all further measurements If the PEAK key is pressed again P H mode i...

Страница 6: ...or the photo detector will vary according to operational conditions but generally the sensitivity decreases in direct proportion to the product of luminous intensity by the operational time In order to maintain the basic accuracy of the instrument a periodical calibration is recommended 9 Recommended illumination Locations Lux NOTE When the photo detector is covered the instrument will always disp...