6 VERSA-KWRL2 

SATEL 

3.  Click on the “Delete

 

button. 

4.  The “Confirm” window will open. 
5.  Click on the “Yes” button. 
6.  The “Confirm” window will close. 
7.  Click on the “Write” button to save the changes to the controller and control panel. 

3.2.2  Manipulator LCD 

You can remove wireless keypads in the service mode by means of the “Remove device” 
function (

“2.Hardware” 

“1.Kpds. & exps.” 

“3.Wireless mod.” 

“3.Remove device”). 

1.  Having started the function, use the 

 and 

 keys to select the keypad you want to 

remove. 

2. Press 

3.  A prompt will be displayed asking you whether to remove the keypad and the serial 

number of the keypad being removed. 

4. Press 

.  

4.  Configuring 

You can configure the wireless keypad settings by using a computer with DLOADX program 
installed, or an LCD keypad. 

4.1  Settings stored in ABAX 2 / ABAX controller 

The settings can be configured: 

 DLOADX program: 

“VERSA – Structure” window 

“Hardware” tab 

“Expansion 

modules” branch 

[controller name]

 

“LCD-WRL” tab (see: Fig. 3), 

 LCD 

keypad: 

“Service mode” 

“2.Hardware” 

“1.Kpds. & exps.” 

“3.Wireless dev.” 

“2.Config.device” 

[wireless keypad name]

4.1.1  Description of parameters and options 

Presence contr.

 – if this option is enabled, the keypad presence is being monitored. If there 

is no transmission from the keypad for 20 minutes, missing keypad will be reported. 

Wake-up

 [Wake up] – the maximum time period for which the keypad can be woken up 

automatically. If you enter a value different from 0: 
–  the keypad will be woken up automatically when an alarm occurs or an entry delay or an 

exit delay begins,  

–  the CHIME from zones will also be signaled when the keypad is in the sleep mode.  
If you enter 0, the keypad will not be woken up automatically. 

If a value different from 0 is preset for the “Wake-up” parameter, the keypad will 
be awaiting for transmissions with information on events. As a result, the 
energy consumption will be growing and the battery life will be considerably 
reduced. 

The keypad is woken up not more frequently than every 30 seconds. If the event that 
is to wake up the keypad occurs before the 30 seconds have elapsed since the last 
automatic wake-up, the keypad will stay asleep. 

Card reader 

– if this option is enabled, the card reader is supported. 

Содержание VERSA-KWRL2

Страница 1: ...VERSA KWRL2 Wireless keypad Firmware version 3 00 versa kwrl2_en 04 19 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel pl...

Страница 2: ...improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on our website Pleas...

Страница 3: ...roller must be connected to the communication bus of the VERSA VERSA IP VERSA Plus alarm control panel In the ACU 220 ACU 280 controller switch 9 must be set in OFF position and switch 10 must be set...

Страница 4: ...urs or an entry delay or an exit delay begins see description of the Wake up parameter section Settings stored in ABAX 2 ABAX controller p 6 When the keypad is in the wake up mode it works in much the...

Страница 5: ...ttery improperly Be particularly careful during installation and replacement of the batteries The manufacturer is not liable for the consequences of incorrect installation of the battery The used batt...

Страница 6: ...wall different for plaster wall etc When installed the device must withstand a pull off force of at least 50 N 10 Put the cover on the catches and snap the enclosure shut 11 Lock the cover using screw...

Страница 7: ...ypad data will be automatically written to the control panel 3 1 2 LCD keypad You can add wireless keypads in the service mode by means of the New device function 2 Hardware 1 Kpds exps 3 Wireless mod...

Страница 8: ...Kpds exps 3 Wireless dev 2 Config device wireless keypad name 4 1 1 Description of parameters and options Presence contr if this option is enabled the keypad presence is being monitored If there is no...

Страница 9: ...signal of zones Zone chime the keypad can audibly signal violation of selected zones If the zone is armed violation will not trigger the CHIME signal The wireless keypad signals the CHIME from zones n...

Страница 10: ...are fully armed if the option is disabled the LED goes off after just one of the partitions is armed in any mode Fig 4 DLOADX program keypad settings stored in the control panel Show code entering Cod...

Страница 11: ...ssages Partitions Part alarm msg if this option is enabled messages on partition alarms will be displayed they contain the name of partition Zones Zone alarm msg if this option is enabled messages on...

Страница 12: ...3 Proximity cards Arming Card hold down if you select this option the user will have to bring the card close to the keys and hold it still for about 3 seconds to arm the system Card read if you select...

Страница 13: ...reat each key pressing exactly in the same way When in the wake up mode the wireless keypad works much in the same way as the wired LCD keypad For how to use the keypad please refer to the control pan...

Страница 14: ...nt consumption BT2 battery card reader disabled 30 mA Maximum current consumption BT2 battery card reader enabled 40 mA Environmental class according to EN50130 5 II Operating temperature range 10 C 5...

Отзывы: