background image

 

 

VD-1 

VIBRATION DETECTOR AND MAGNETIC CONTACT 

 

vd1_en 07/16 

The VD-1 detector senses vibrations associated with attempts to force a door or window 
(vibration detector), as well as detects opening of a door or window (magnetic contact). 

1.  Features 

 Piezoelectric 

sensor. 

  Advanced processing of signal from piezoelectric sensor. 

  Two reed switches allowing to select the magnet installation manner. 

 LED 

indicator. 

  Tamper protection against cover removal and tearing enclosure from the wall. 

2.  Specifications 

Supply voltage ................................................................................................... 12 V DC ±15% 
Standby current consumption .........................................................................................3.5 mA 
Maximum current consumption.......................................................................................5.4 mA 
Relay contacts rating (resistive load) .............................................................. 40 mA / 16 V DC 
Typical detection range of vibration detector, depending on mounting surface: 

concrete ........................................................................................................... 1.5 m 
brick ................................................................................................................. 2.5 m 
wood ................................................................................................................ 3.5 m 
steel .................................................................................................................... 3 m 
PVC ............................................................................................................... 2.25 m 

Environmental class according to EN50130-5 ......................................................................... II 
Operating temperature range.............................................................................-10 °C...+55 °C 
Detector enclosure dimensions......................................................................26 x 112 x 29 mm 
Surface mounted magnet enclosure dimensions .............................................26 x 13 x 19 mm 
Surface mounted magnet spacer dimensions.................................................26 x 13 x 3,5 mm 
Flush mounted magnet enclosure dimensions.................................................28 x 10 x 10 mm 
Weight................................................................................................................................. 64 g 
 

The declaration of conformity may be consulted at www.satel.eu/ce 

3.  Description 

Alarms 

The detector reports alarm in the following cases: 

 registering 

of 

strong 

vibrations, 

  registering of a predefined number of weak vibrations, 

  opening reed switch contacts after removal of magnet, 

  opening the tamper contact (tamper alarm). 