SATEL-TR489
Integration Guide, Version 0.9
23
Component values of the equivalent schematics:
Component
Value
Note
C1
6.8 pF
C2
1 uF
L1
220 nH
L3
1000
Ω
+- 25%
Measured Impedance at 100 MHz
C7
100 nF
L4
1000
Ω
+- 25%
Measured Impedance at 100 MHz
R1
330
Ω
R2
100 k
Ω
L5
1000
Ω
+- 25%
Measured Impedance at 100 MHz
R3
330
Ω
R4
100 k
Ω
L6
1000
Ω
+- 25%
Measured Impedance at 100 MHz
R5
330
Ω
L7
1000
Ω
+- 25%
Measured Impedance at 100 MHz
R6
330
Ω
R7
100 k
Ω
L8
1000
Ω
+- 25%
Measured Impedance at 100 MHz
R8
1 k
Ω
R9
>1 M
Ω
R10
100 k
Ω
4.4
RF interface
The antenna interface is a 50
Ω
coaxial connector. Matching networks are not included on the
module and should be placed in the host application if the antenna is not 50
Ω
. The HIROSE
U.FL compatible connector is located on the TOP side of the board.
NOTE! The used connector has gold plated contacts - whereas a standard HIROSE U-FL has
silver plated contacts.
If silver - gold joints are not allowed in your product, use gold plated cable-connector to mate to
this device.
NOTE!
Setting the transmitter output power to such a level that exceeds the regulations
set forth by local authorities is strictly forbidden. The setting and/or using of non-
approved power levels may lead to prosecution. SATEL and its distributors are not
responsible for any illegal use of its radio equipment, and are not responsible in
any way of any claims or penalties arising from the operation of its radio
equipment in ways contradictory to local regulations and/or requirements and/or
laws.