Ground Start
– with this option enabled, the control panel will use the Ground Start method
to obtain signal on the telephone line (by grounding temporarily the telephone line wires).
Enable this option, if required by your phone service provider.
No dial tone test
[No dialton.tst] – with this option enabled, the control panel will not perform
the test for dial tone before dialing the number and will start dialing the number 5 seconds
after going "off hook". This makes it possible for the control panel to dial the number when
some non-standard tones occur after going off hook (e.g. interrupted tone). When this
option is disabled, the control panel will start dialing the number 3 seconds after going off
hook, provided that the dial tone is present.
No answer tone test
[No answer test] – with this option enabled, in case of notifying by
means of voice messages, the control panel will not perform the test for "off hook"
condition. The voice message will be played back 15 seconds after completion of the
number dialing
.
Double voice message
[Dbl. voice msg.] – with this option enabled, the voice message is
played back twice during telephone messaging.
Double call
– with this option enabled, the control panel must be called twice for the modem
communication to be established. The first time you must wait for the preprogrammed
number of rings and hang up. Then you must call back within three minutes and the
control panel will answer the call immediately. This solution makes it possible to connect
after the control panel some additional devices which will be activated after a preset
number of rings (e.g. answering machine, fax, etc.).
Pulse 1/1.5 (off 1/2)
– this option applies to dialing the telephone numbers by using the pulse
mode. Before you enable it, make yourself familiar with the valid standard of pulse dialing.
5.2 Printer options
Printing
– the option enables on-line events printout by the printer connected to the RS-232
port of control panel mainboard.
5.2.1 Printout options
Include reporting status
[Monitor.status] – on the printout will appear the information if the
particular event was sent to the monitoring station (printout of the event information will
take place not immediately but after transmission to the station has been completed).
Print names / descriptions
[Names/descript] – determines if, besides the numbers of zones,
outputs, modules and users, also their names and descriptions are to be printed.
Wide paper
– printout width will be 132 columns (if the option is disabled: 80 columns).
2400 bps (off:1200 bps)
– data will be sent to RS-232 port at a rate of 2400 bps (if the
option is disabled - at a rate of 1200 bps).
CR+LF (off: CR)
– parameter determining the control mode of paper feed in the printer.
Use parity bit
– the parity check of data transferred from the control panel to the printer is
enabled.
Parity EVEN (off: ODD)
– option determines the mode of parity check of data transferred
from the control panel to the printer. The option is relevant only if the U
SE PARITY BIT
option
is active.
The other parameters of RS-232 transmission are permanently programmed (8 data
bits, 1 stop bit).
All the parameters regarding transmission through RS-232 (i.e. transmission rate,
CR+LF, parity, data bits and stop bits) are to be set identically on the control panel and
on the connected printer. Otherwise the printer will not operate at all, or the printout
will be illegible.