Satel ASD-250 Скачать руководство пользователя страница 1

 

 

 

 
 
 
 
 
 

ASD-250 

 

Wireless smoke detector 

 

 

 

 

 
 
 
 

 

 
 
 
 
 
 
 
 
 
 

 

Firmware version 1.00 

asd-250_en 10/19 

SATEL sp. z o.o. • ul. Budowlanych 66 • 80-298 Gda

ń

sk • POLAND 

tel. +48 58 320 94 00 

www.satel.eu 

Содержание ASD-250

Страница 1: ...ASD 250 Wireless smoke detector Firmware version 1 00 asd 250_en 10 19 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...

Страница 2: ...ms to continually improve the quality of its products which may result in changes in their technical specifications and software Current information about the changes being introduced is available on...

Страница 3: ...the ABAX 2 system Transmission channel diversity 4 channels for automatic selection of the one that will enable transmission without interference with other signals in the 868 MHz frequency band ABAX...

Страница 4: ...soiling 2 short flashes every 30 seconds low battery 3 short flashes every 30 seconds alarm ON for 5 minutes Working in ABAX 2 ABAX system LED indicates low battery 3 short flashes every 30 seconds al...

Страница 5: ...he detector the ECO option When the ECO option is enabled the periodical communication takes place every 3 minutes Thus the battery life can be increased as much as fourfold The option is only availab...

Страница 6: ...sed without the battery inserted Do not install the battery if the sounder is disconnected There is a danger of battery explosion when using a different battery than recommended by the manufacturer or...

Страница 7: ...gth The ARF 200 tester makes it possible to check the radio signal strength at the place of future installation without having to put the detector there 9 Remove the detector cover 10 Use wall plugs a...

Страница 8: ...ith the electronics board Fig 9 6 Push outward the catches Fig 10 and take out the electronics module with the optical chamber Fig 11 7 Push outward the catch securing the optical chamber cover Fig 12...

Страница 9: ...hort beeps every 30 seconds the battery must be replaced 1 Start the service mode in the control panel if the controller is connected to a SATEL alarm control panel 2 Remove the screw fastening the co...

Страница 10: ...rformance 1438 CPR 0645 for the construction product ASD 250 Wireless Smoke Detector confirming its compliance with the requirements of EN 14604 2006 The CNBOP PIB Certification Body in J zef w has te...