APS-412
Power supply
EN
Firmware version 1.02
aps-412_en 08/22
SATEL sp. z o.o.
• ul. Budowlanych 66 • 80-298 Gdańsk • POLAND
tel. +48 58 320 94 00
www.satel.eu
Страница 1: ...APS 412 Power supply EN Firmware version 1 02 aps 412_en 08 22 SATEL sp z o o ul Budowlanych 66 80 298 Gda sk POLAND tel 48 58 320 94 00 www satel eu...
Страница 2: ...zed by the manufacturer shall void your rights under the warranty SATEL aims to continually improve the quality of its products which may result in changes in their technical specifications and softwa...
Страница 3: ...S 1 Features 2 2 Description of the power supply 3 2 1 Electronics board 3 3 Configuration 4 4 Installation 5 5 Standard requirements for battery 8 6 Battery testing by the power supply 8 7 Specificat...
Страница 4: ...nnect system Ability to work without a battery connected Output current operation with battery 3 5 A 3 A operation without battery 4 A Battery charging current 0 5 A 1 A selectable Connector for integ...
Страница 5: ...tatus ON battery OK or the battery testing mode disabled flashing low battery battery voltage below 11 5 V OFF no battery or blown F3 fuse green LED AC power status ON AC power OK flashing no AC power...
Страница 6: ...th SATEL devices It is used to power SATEL devices and transmit information on the power supply status The SATEL device must have the same connector The connecting cable is included in the set Fig 4 F...
Страница 7: ...ircuit For a backup power supply use a 12 V sealed lead acid battery or other 12 V battery with similar charging characteristics The battery capacity must be selected to match the current consumption...
Страница 8: ...e through the cable gland Fig 8 8 Screw the 230 VAC power wires to terminals phase conductor to L terminal neutral conductor to N terminal and protective conductor to PE terminal Fig 9 9 Screw the ele...
Страница 9: ...SATEL APS 412 7...
Страница 10: ...Ah 1 A or 0 5 A 3 A 24 Ah 1 A or 0 5 A 2 A 12 Ah 1 A or 0 5 A 1 A Table 2 6 Battery testing by the power supply After starting the power supply provided that the battery testing mode is enabled and a...
Страница 11: ...ery connected 3 5 A 3 A Battery charging current selectable 0 5 A 1 A Current consumption of power supply circuits 57 mA Battery failure voltage threshold 11 5 V 10 Battery cut off voltage 10 5 V 10 O...