The AGD-100 detector enables detection of a break of plate, tempered and laminated glass. 
It is designed for operation within the ABAX two-way wireless system. It is supported by the 
ACU-100 controller with firmware version 1.06 (or newer) and by the INTEGRA 128-WRL 
control panel. This manual applies to the detector with electronics version 1.4D or newer. 

1.  General 

The detector will report the alarm when a low frequency sound (impact) 
followed by a high frequency sound (glass-break) are registered. The 
high-frequency channel is analyzed for four seconds from receiving 
the low-frequency sound wave, caused by the impact. Sensitivity of 
the high-frequency channel is set by radio. 
The LED is only functioning in the test mode: 

  it is lit up for 80 milliseconds, when the detector is being polled; 

  it is lit for 500 milliseconds after registering a low-frequency sound; 

  it is lit for 2 seconds after registering a high-frequency sound or 

opening the tamper contact. 

Fig. 1: View of detector electronics board: 

 microphone. 

 tamper contact, which opens when the cover is removed or the unit 

is removed from its mounting surface. 

 CR123A 3 V lithium battery, ensuring operation for approx. 2-year 

period. The detector checks the battery status. When the voltage is 
lower than 2.6 V, the transmission sent during polling contains 
information on low battery. 

2.  Installation 

The detector is designed for indoor installation, attached directly to the wall. The protected 
glass surfaces must remain within the device detection range. 

Curtains, drapes, furniture upholstery, acoustic tiles, etc. absorb the sound and 
adversely affect the detection range. 

Be particularly careful during installation and replacement of the battery. The 
manufacturer is not liable for the consequences of incorrect installation of the 
battery. 

The used batteries must not be discarded, but should be disposed of in 
accordance with the existing rules for environment protection. 

1. Open the enclosure. 