background image

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 

Access Control Panel 

ACCO-NT 

 
 
 

Installer Manual 

 
 
 
 
 
 
 
 
 
 
 
 

Firmware version 1.12 

acco-nt_en 11/17 

 
 
 

SATEL sp. z o.o. 

ul. Budowlanych 66 

80-298 Gda

ń

sk 

POLAND 

tel. +48 58 320 94 00 

www.satel.eu 

Содержание ACCO-NT

Страница 1: ...Access Control Panel ACCO NT Installer Manual Firmware version 1 12 acco nt_en 11 17 SATEL sp z o o ul Budowlanych 66 80 298 Gdańsk POLAND tel 48 58 320 94 00 www satel eu ...

Страница 2: ... manufacturer shall void your rights under the warranty The device uses FreeRTOS v 6 1 0 licensed under Modified GPL license www freertos org SATEL s goal is to continually upgrade the quality of its products which may result in alterations of their technical specifications and firmware The current information on the introduced modifications is available on our website Please visit us at http www ...

Страница 3: ...ddressing the devices connected to expander bus 11 6 7 Connecting the devices to control panel and expander inputs 12 6 8 Connecting to the Ethernet network 12 6 9 Connecting the power supply 12 6 9 1 Control panel power up start up procedure 12 7 Numeration of inputs and outputs in the system 12 8 Configuring network settings of the ACCO NT control panel 13 8 1 System requirements 13 8 2 Installi...

Страница 4: ...O KPWG ACCO KPWG PS expansion modules INT E INT O INT PP INT RX S firmware version 1 02 or newer INT ORS INT IORS 2 Features System structure Any number of objects in the system Any number of access control panels in the object the number of devices is only limited by server performance Up to 255 access control modules supported by the access control panel Up to 255 zones in 1 access control panel...

Страница 5: ...administrator 8 thousand users in zone control panel Up to 65 thousand users in the entire ACCO NET system User can be assigned code proximity card passive transponder which may be in the form of card key tag etc DALLAS chips iButtons keyfob Up to 4 proximity cards DALLAS iButtons can be assigned to each user Time schedules Up to 256 access calendars Up to 256 weekly schedules Up to 256 daily sche...

Страница 6: ...he control panel and RS 485 buses computer and server power supply system microSD card Electrical protection for all inputs and outputs as well as communication buses Connector socket for APS 412 power supply Option to install the control panel in OPU 3 P or OPU 4 P enclosure 3 Mainboard description Explanations for Fig 1 connector socket for APS 412 power supply LEDs LD1 LD8 indicating the curren...

Страница 7: ...tput for devices connected to expander bus CK expander bus clock DT expander bus data 3 1 MicroSD memory card The purpose of microSD memory card is to store the configuration data of ACCO NET system save the events from access control panel and downloaded from access control modules The control panel supports microSD and microSDHC memory cards Do not remove the memory card when the access control ...

Страница 8: ...he access control modules connected to the first RS 485 bus RS2 LED flashing communication with the access control modules connected to the second RS 485 bus proceeds normally OFF no communication with the access control modules connected to the second RS 485 bus LAN LED flashing communication with Ethernet network proceeds normally OFF no communication with Ethernet network SVR LED flashing commu...

Страница 9: ...y INT RX S 433 MHz keyfobs receiver expansion module Enables operation of the access control system using the 433 MHz keyfobs INT E Input expander Adds 8 programmable hardwired inputs NO NC to the system INT O Output expander Adds 8 programmable hardwired outputs to the system INT PP Input output expander Adds 8 programmable hardwired inputs NO NC and 8 programmable hardwired outputs 4 relay and 4...

Страница 10: ...uts is 0 5 A in total 6 3 Cabling For the RS 485 communication bus use the twisted pair type of cable e g UTP unscreened twisted pair cable To make connections between the control panel and the devices connected to the expander bus it is advisable to use the unshielded non twisted cable using the twisted pair type of cable e g UTP STP FTP is not recommendable Select cross section of the power supp...

Страница 11: ...e The access control modules should be power supplied as per description contained in the manuals delivered with respective devices The access control modules should be connected to the ACCO NT control panel using the bus topology using the star topology is not recommended The RS 485 bus structure is shown in Fig 2 6 5 1 Addressing the access control modules When connecting the modules to the buse...

Страница 12: ...an additional cable The modules in the drawing are designated by ordinal numbers not addresses 6 6 Connecting the devices to expander bus The bus wires must be run in one cable The total length of expander bus must not exceed 1000 m The expanders should be power supplied in accordance with description contained in the manuals delivered with respective devices Table 2 shows the number of conductors...

Страница 13: ...nders directly powered from the control panel Fig 4 The way of connecting expanders using another power source 6 6 1 Addressing the devices connected to expander bus Each device to be connected to the expander bus must have its own individual address from the 0 to 31 range The addresses of the devices must not repeat the control panel does not ...

Страница 14: ...port on control panel electronics board Use a 100Base TX standard compliant cable identical to that used for connecting computers to the network 6 9 Connecting the power supply Do not connect power supply untill the installation work is completed The APS 412 power supply unit manufactured by Satel is required to power the ACCO NT control panel For description of the power supply installation pleas...

Страница 15: ... the computer by means of the USB cable the supply outputs expander bus and RS 485 buses are disabled 1 Connect the USB MINI B port on control panel electronics board with the computer USB port by means of a suitable cable All LEDs indicating the current status of control panel and communication will come on for 2 seconds and then only the PWR LED will come on steady 2 The Windows system will auto...

Страница 16: ...c IP address select this field if the IP address data of control panel subnet mask and gateway are to be entered manually IP address enter the control panel IP address in this field The field is available if the Static IP address option has been selected Mask enter in this field the mask of subnet in which the control panel is to operate The field is available if the Static IP address option has b...

Страница 17: ...the control panel clock Firmware version control panel program version build version and release date Network Configuration IP address IP address of the control panel Mask mask of subnet in which the control panel is used Gateway the IP address of network device by means of which the other devices of the local network communicate with devices in other networks DNS IP address of the DNS server used...

Страница 18: ...t on the module operation The access control modules will enter the offline mode also during remote firmware update of the module connected to the same ACCO NT control panel 10 Control panel firmware update 10 1 Local update of the control panel firmware On the www satel eu website you can find the latest version of ACCO NT control panel firmware and the program for updating control panel firmware...

Страница 19: ...and DT terminals of control panel 3 Short together the control panel CK and DT terminals 4 Power on the control panel All LEDs will come on for 2 seconds and then only the PWR LED will come on steady 5 Open the control panel CK and DT terminals 6 Start the program for updating the control panel firmware and update the control panel firmware according to the procedure described in section Control p...

Отзывы: