SATALARM SA-612 & SA-816 installer manual ver 1.1
To exit the “main programming menu”, press *#+ key.
Note:
If in this section, one of the 2 groups of 2 digits are set both with value 0, then the corresponding partition will try to auto arm after every second if no
activity will be detected in the area.
Section [096] – Walk Test (service mode)
This command allows to the installer to manually enter the “walk test” mode and test the sensors in the system.
Thus, just entering section *096+ could system being in the “walk test” mode. While the system is in the “walk test” mode
any zone violation will produce a “ding sound” on the siren.
After all sensors in the system was tested, press [#] key to exit this testing mode.
After [#] key was pressed, the keypad
buzzer will sound 6 confirmation beeps and exit this section waiting for a new command to enter another section or [#] key to
exit the main programming menu.
Note:
Once the system enters section [096], it will exit this section only after [#] key is entered (the control panel will not leave this section automatically, 2
minutes after the last key pressing any more).
Section [097] - Manually Activation of PC callback
Entering section [097] allows to the installer to manually initiate the PC call to establish the communication between the
control panel and PC. Before entering this section the PC modem must be passed in the waiting status for control panel calls.
Once the installer entered this section, the control panel will dial the “PC phone number”, programmed in section *093+;
while the PC modem is called it will “take” the phone line over and will start to communicate with the control panel. The control
panel and PC will verify each over the passwords (the control panel and PC identification codes within upload/download,
programmed in sections [091] and [092]) and, if the passwords are correctly, the communication between the control panel and
PC will be activated upon the control panel initiating.
Notes:
1.
This function is identical with [*][8][Master Code][097][#] command, which is allowed to the master user, too.
2.
For a successful initiating of the PC callback, the “PC phone number” needs to be programmed in section *093+.
Section [098] PC download acceptance
[*][8][Master Code][098][#]
This command allows to the “master user” to manually trigger the communication between PC and panel. Before entering
this command the PC modem must be already on the phone line and call the control panel.
While PC modem is calling the control panel, just entering this command will manually activate the communication between
PC and panel.
This command is accepted only while the system is partially armed.
Notes:
1.
This command is similar to the one in the installer-dedicated programming section [098].
2.
Manually triggering of the communication between PC and panel is useful when “Panel answers to remote PC calls” option was not enabled by programming
in section [035], which is dedicated to the installer and system parameter programming from PC software is still required.
3.
Within panel programming by PC (Upload/Download) denomination, there are several operations, which any user or the installer can perform them while a
connection between the PC modem and control panel is established.
The following operations can be performed:
-
Uploading the system parameters into “EZcom SA-612P&SA-816P Software”;
-
Downloading the system parameters from “EZcom SA-612P&SA-816P Software” into the control panel;
-
Uploading the event LOG from the control panel into the “EZcom SA-612P&SA-816P Software”
(in a file).
-
System time and date setting by PC;
-
System (or partitions) arming/disarming by PC.
-
Zone bypassing by PC;
-
PGM activation/deactivation by PC (only for PGM outputs defined as “mono-stable”, “bi-stable” or “clock timer” types);
-
Online visualization of the system/partitions status and troubles onto “EZcom SA-612P&SA-816P Software”;
-
Online visualization of the bypassed, alarmed or open zones onto “EZcom SA-612P&SA-816P Software”.