SATALARM SA-612P / SA-816P
12/16-Zone and 2-Partition Alarm Control Panel For your home and office
User’s Guide
Doc ----/ 01.2009/ version 1.1
Страница 1: ...SATALARM SA 612P SA 816P 12 16 Zone and 2 Partition Alarm Control Panel For your home and office User s Guide Doc 01 2009 version 1 1 ...
Страница 2: ...ter code 31 Programming Selective Erasure of the 1 to 4 follow me Phone Numbers 31 Selective Erasure of the follow me phone numbers 32 Simultaneous Erasure of all Follow me Phone Numbers 33 Programming session of the system time and date 33 Ambush Digit Programming master user s submenu 061 34 Other Operation Commands Performed by the master user 34 Section 034 OPTIONS for voice sound dialer 35 Se...
Страница 3: ...96 Walk Test service mode 40 Section 097 Manually Activation of PC callback 40 Section 098 PC download acceptance 40 Sections 099 Voice Sound Reporting and Communication with PC Cancellation 41 Keypad Special alarms 41 Warning Limitations of Alarm Systems 41 ...
Страница 4: ...or first 9 alarms occurred in the system since last arming Up to 8 keypads which can be simultaneously 4 wire coupled to one central unit Keypad protection using micro switch tamper On KP 126PZ KP 164PZ LED keypad Individual zone LEDs from 1 to 12 16 indicating the alarm and faulted status System status LEDs SYSTEM ARMED A and ARMED B READY A and READY B and BYPASS On KP16LCDLB keypads all the sys...
Страница 5: ...ed in 4x2 format Ademco Express 10PPS 20PPS or 40PPS with without parity data of 1800Hz or 1900Hz and handshake of 1400Hz or 2300Hz Periodical test reporting with steps of up to 255 minutes or hours time adjustment of the starting and either unconditionally reporting or only while armed status Programmable reporting codes for zone alarming zone restore and zone bypassing automatic from swinger shu...
Страница 6: ...ming chime function activating stay intellizone sensor under test as well as individually selectable zone response time Zone bypassing automatic from swinger shut down or caused by home arming if the zones have the stay attribute activated and manually by the users 2 real partitions which can be armed disarmed independently from each other allowed by user rights Individually programmable exit and ...
Страница 7: ...ions All the user code rights are assigned to the keyfob functions too Easy enrollment of the keyfob and or proximity card in the time of entering or modifying user code procedure performed by master user User number of the appropriate associated keyfob or card that was used is stored in control panel event log and reported to the Central Station having precise information about the user that oper...
Страница 8: ...try exit door Keypad types The next keypad models are available KP 126Pz keypad with 12 zone LEDs and 6 status LEDs 2 hardwired zones for SATALARM SA 612P panel KPKP 164Pz keypad with 16 zone LEDs and 4 status LEDs 2 hardwired zones for SATALARM SA 816P and SA 816Pw panels KP16LCDLB LCD keypads compatible with both panels SATALARM SA 612P and SA 816P Keypad layout KP 126P KP 164P KP16LCDLB ...
Страница 9: ...e partition is ready for arming all zone loops are closed except at least one which allow forced arming feature OFF at least one zone is open and it doesn t allow forced arming feature c While the system is totally disarmed and finds itself within one of the Programming Menus only for READY A ON while the master user is being within one of the master user s programming procedures for modifying the...
Страница 10: ...manually bypassed by user and or at least one interior zone bypassed by control panel o Alternate 3 seconds OFF 3 seconds blinking if both conditions are present system troubles and or registered alarm events and bypassed zones C While the system is totally disarmed Blinking when the user is being within one of the next menus Zone bypassing System trouble displaying Alarm memory displaying or Prog...
Страница 11: ...OFF they are displaying certain parameters status activate deactivate while the installer is being within certain sections of programming menu of the system parameters Displayed messages on KP16LCDLB keypads several situations Press key and the display will invite you to choose one of the 10 menu commands The LCD keypad helps you remember what the menu commands available are Pressing the key on th...
Страница 12: ...s if you made mistakes by pressing wrong key within any of commands and or user code entering press the to abandon the initiated procedure The panel will come back in the stand by state waiting for commands The list of messages that can be seen on the LCD keypads display is much longer but easy to understand ...
Страница 13: ... and Zone Bypassing Unbypassing All user codes have ambush capability by pressing the key which corresponds to the ambush digit before the 4 or 6 digits of any user code the control panel will transmit a special code to the central station if the control panel is programmed to report events to a central monitoring station This means that user was under duress ambush Thus the dispatcher will be inf...
Страница 14: ...as home offices or warehouse buildings If the system is not partitioned all user codes and features will be recognized as belonging to the system doesn t matter if user codes have the right of access to partition B or zones are assigned by program to partition B How does a partitioned system work Users can only arm disarm partitions in which they have been given the right to access by the means of...
Страница 15: ...te loss If at least one zone was bypassed by users the BYPASS LED will be ON only KP 126Pz KP 164Pz The default exit delay time is 60 seconds see the section 037 of the main programming menu After the exit delay elapsed all status LEDs will turn OFF except the ARMED A and or B ones which will remain ON until disarming signaling the system is away armed and on LCD displays you can see one of these ...
Страница 16: ...autoarming is not enabled or if the zone doesn t allow forced arming If this occurs the control panel will report fail to autoarm code and the system partition will not arm for a new inactivity time The type of autoarming is regular or stay and is dependent on the appropriate options within 030 sections Program the inactivity autoarming time as it is described in 090 section Instant Stay Arming 1 ...
Страница 17: ...164Pz The BYPASS LED will turn OFF only after disarming If during any home arming period at least one alarm or trouble occurs in the system then the SYSTEM LED will start to blink The yellow SYSTEM LED will stop to blink only after another system partition arming or after viewing the first 9 alarm memory occurred from the last arming of panel partitions After the exit delay elapsed the READY LED w...
Страница 18: ...YSTEM LED will turn OFF only when disarming Blinking in case there are troubles in the system AC power loss low voltage on battery fail to communicate event BELL trouble phone line trouble or system time and date loss the yellow SYSTEM LED will stop to blink only after all troubles in the system will be solved Alternating 3 seconds ON 3 seconds blinking in case both conditions are met in the same ...
Страница 19: ...ands is followed by a time of 5 seconds in which the user has to choose the disarmed partitions to be armed without codes to arm the A partition the user must press 1 key and to arm the B partition the user must press 2 key please note that if the user is pressing the key which corresponds to an armed partition the keypad buzzer will sound a long beep On LCD keypads after pressing the and 0 keys o...
Страница 20: ...he system since the last arming time by the use of the 5 command If no alarms occurred during the previous armed period and the SYSTEM LED is still blinking after disarm see system trouble status by using the 4 command The SYSTEM LED blinking can be seen only on KP 126P KP 164P and KP16LCDLB In case of using KP16LCD the user should use the 5 commands after all disarms of system partition s in orde...
Страница 21: ...ssed or un bypassed by the use of keys 1 to 6 To switch to High Zones Un Bypassing mode user has to press the key The keypad will confirm entering this mode with 3 beeps In this mode zone LEDs 1 to 6 and keys 1 to 6 are used to perform the bypassing or un bypassing procedure for zone 7 to zone 12 respectively The difference between these 2 modes on a LED keypad is the 3 or 6 confirmation beeps If ...
Страница 22: ...failed to transmit events to CS2 after 8 attempts 2 nd CS phone number will not answer either after the 8 th call in case of the split reporting was selected The LED will turn OFF only after a successful transmitting to both CS1 and CS2 Zone 4 LED System time and date not programmed Power ON The control panel s internal clock must be re programmed because the control panel was powered This trouble...
Страница 23: ...pad because the keypad is powered exactly from this power supply and an overload on AUX is stopping keypad powering until overload gets removed 2 If any trouble condition occurs it needs to be solved before arming to assure a proper function for system 3 If there are alarms in the memory the SYSTEM LED will turn blinking too if the SYSTEM LED is blinking just because of at least one alarm occurred...
Страница 24: ...t of the user s view and he she wants to be notified whenever the doors of those zones are opened Chime feature can be activate deactivate from PC software too Activation Deactivation of PGM Outputs 9 User Code If a user code maintenance code included has the appropriate rights enabled by programming then the respective user may use 9 User Code command and perform the following operations activati...
Страница 25: ...ccessful command of PGM2 activation deactivation is followed by an automatic exit from menu after about 1 second like after key pressing after 1 sec 4 In order to activate deactivate PGM3 defined as mono stable bi stable or clock timer types the user should press the 3 key and the zone 3 LED will turn ON OFF If the zone 3 LED is ON means PGM3 is activated and if the zone LED is OFF means PGM3 is d...
Страница 26: ... second like after key pressing after 1 sec Notes a In case one user is trying to activate deactivate the PGM outputs and the user code hasn t the proper right enabled the keypad buzzer will sound a long error beep and will reject that command b The keypad buzzer will sound a long error beep and the panel will reject that command too if users try to activate deactivate any PGM output which was not...
Страница 27: ... me phone numbers master user s submenus from 051 to 054 4 Simultaneous Erasure of all follow me phone numbers master user s submenu 050 5 Programming session of the system time and date master user s submenu 060 6 Ambush Digit Programming master user s submenu 061 While the system is being within master user s programming menu in order to program the 01 to 45 user codes the follow me phone number...
Страница 28: ... for first digit for new value of the selected user code one of the 2 to 4 zone LEDs or to 6 for 6 digit codes Blinking That means the selected user code is programming and the control panel is waiting for corresponding digit for new value of the selected user code 1 Programming Erasing of the selected user code may be skipped by key pressing 1 1 After key pressing if the selected user code was pr...
Страница 29: ...led and if the zone LED is OFF means the right is disabled By key pressing RIGHTS1 set of the user code can be maintained as it was previously established 3 1 The rights of the user code are displayable on 1 to 8 options in order to turn the rights activate deactivate the installer should press the 1 to 8 keys and the appropriate right will turn ON OFF For LED keypads if a zone LED is ON while the...
Страница 30: ...r to turn the rights activate deactivate the installer should press the 1 to 2 keys and the appropriate LED will turn ON OFF If the a zone LED is ON that means the appropriate right is enabled and if the zone LED is OFF that means the right is disabled RIGHTS 3 set for selected user code RIGHTS 1 enabled disabled Start guardian rounds RIGHTS 2 enabled disabled Finish guardian rounds RIGHTS 3 enabl...
Страница 31: ... 0 4 and 9 The keypad buzzer will sound 6 confirmation beeps and the control panel will go back into master user s programming menu Any user code from 01 to 45 can be selected in order to get a new value or press key to exit the master user s programming menu Programming Selective Erasure of the 1 to 4 follow me Phone Numbers 7 Master Code 05X Phone number X or CODE Master Code 05X Phone number X ...
Страница 32: ...s programming menu only after key pressing 4 In order to erase the selected phone number you should enter key instead of sequence of maximum 15 digits while the control panel just entered the corresponding programming erasing session of the selected phone number The keypad buzzer will sound 6 confirmation beeps and the control panel will go back within master user s programming menu after pressing...
Страница 33: ... only if the appropriate option does not disabled by programming see the appropriate option within 020 section While the system is being within master user s programming menu in order to program the system time and date the master user should select 060 submenu While the system is being within master user s programming session of the system time and date the keypad LEDs status will be as follows R...
Страница 34: ...on beeps and the control panel will go back within master user s programming menu keeping the old value for system time and date 3 Leave the master user s programming menu by key pressing Ambush Digit Programming master user s submenu 061 7 Master Code 061 or CODE Master Code 061 where CODE is the key labeled CODE While the system is being within master user s programming menu in order to program ...
Страница 35: ...panel and PC 21 Section 100 Reading event LOG Notes 1 Master user s entering of these commands is similar to the entering the same programming sections which are dedicated to the installer 2 After the master user enter 8 Master Code command if he is trying to select another programming section than the previous then the keypad buzzer will sound a long error beep and the panel will reject the comma...
Страница 36: ... main board or it was deactivated the panel will report upon remote interrogation calls or to the follow me phone numbers only by specific synthesis sounds Section 042 Number of voice or sound dialing sequences Time of the Voice or Sound Reporting Enter 2 groups of 2 digits the first being the number of times the voice message or the synthesis sounds will be repeated for programmed phone numbers 0...
Страница 37: ...inute 00 to 59 for finishing moment The following sequence will be introduced __ __ __ __ __ __ __ __ not programmed by default The keypad buzzer will sound 3 beeps after each 2 digit group and 6 beeps after the last one Then the panel exits the section and will wait for a new command To exit the main programming menu press key Section 081 Activation Deactivation Moments of PGM1 defined as clock t...
Страница 38: ...00 to 59 for deactivation moment The following sequence will be introduced __ __ __ __ __ __ __ __ not programmed by default The keypad buzzer will sound 3 beeps after each 2 digit group and 6 beeps after the last one Then the panel exits the section and will wait for a new command To exit the main programming menu press key Section 085 Activation Deactivation Moments of PGM5 defined as clock time...
Страница 39: ...__ __ __ __ not programmed by default The keypad buzzer will sound 3 beeps after each 2 digit group and 6 beeps after the last one Then the panel exits the section and will wait for a new command To exit the main programming menu press key Section 089 Hour Minute for First Periodical test Enter 2 groups of 2 digits the first 2 digits for hour 00 to 23 and the second 2 digits for minute 00 to 59 wh...
Страница 40: ...e control panel and PC will be activated upon the control panel initiating Notes 1 This function is identical with 8 Master Code 097 command which is allowed to the master user too 2 For a successful initiating of the PC callback the PC phone number needs to be programmed in section 093 Section 098 PC download acceptance 8 Master Code 098 This command allows to the master user to manually trigger ...
Страница 41: ...cur by activating the correspondingly 24h defined zones or by simultaneously pressing a combination of keys from keypad 1 3 Medical Emergency alarm 4 6 Maintenance Request 7 9 Fire alarm Panic alarm In order to stop any alarm status enter key followed by any 4 or 6 digit user code from 1 to 45 Note The keypad panic alarm should be used in emergency situations when the user is threatened and the po...
Страница 42: ...ng devices such as sirens bells or horns may not alert people or wake up sleepers who are located on the other side of closed doors If the warning devices sound on a different level of the residence from the bedrooms then they are less likely to waken or alert people inside the bedrooms Even persons who are awake may not hear the warning if the alarm is muffled by noise from a stereo radio air con...