Safety Instructions

1.3 

Symbols Used

1.3.1 

Warnings in Operation Descriptions

 CAUTION

Denotes a danger with risk of moderate or minor injury may result if it is 

not

 

avoided.

1.3.2  Other Symbols

 

t  

Required action: Describes activities that must be carried out. 
The actions in the sequence must be carried out in succession.

 

y

 

Result: Describes the result of the activities carried out.

2  Safety Instructions

2.1 

General Function

The product is used for vacuum filtration of liquids, e.g. cell culture media. 
The filtration applications, the liquids used, and the filling volume must be 
suitable for the product. 
The product must be connected to a vacuum source during filtration. 

The liquid to be filtered must be poured into the funnel. 

The product can be inserted into a support manifold. In this way, the 
support manifold applies a vacuum to the product and filtration can be 
performed simultaneously. The support manifold must be suitable for 

the product.

If the product is used without a support manifold: The product must be 
connected to a vacuum source, e.g. a vacuum pump, via a vacuum tube. 

The vacuum source must be suitable for the product.

The product is intended for single use and must be disposed of after 

one use.

The product is intended exclusively for use in accordance with these 
instructions. Any further use beyond this is considered 

improper

Operating Conditions for the Product

The product may only be used for research purposes. The product is 

not

 

suitable for diagnostic applications.
The product may only be used with the equipment and under the operating 
conditions described in the Technical Data section of these instructions. 

Содержание Sartolab BT 1000

Страница 1: ...Instructions for Use Sartolab RF BT RF 50 1000 BT 150 1000 Filtration Unit for Vacuum Filtration 1000096582...

Страница 2: ......

Страница 3: ...n 9 3 5 Product Symbols 9 4 Process Preparation 10 4 1 Scope of Delivery 10 4 2 Unpacking 10 4 3 Assembling the Receiver Bottle Sartolab BT 150 1000 Only 10 4 4 Inserting Product into a Rack Sartolab...

Страница 4: ...perating Conditions 16 8 4 1 Operating Pressure for Vacuum Source 16 8 4 2 Filtration Applications 16 8 4 3 Liquids 17 8 4 4 Filtration Capacity 17 8 5 Membrane Filter 19 8 6 Sterility 20 8 7 Approved...

Страница 5: ...E Sartolab BT 250 180E13 E Sartolab BT 500 180E14 E Sartolab BT 1000 180E15 E 180F15 E 1 2 Target Groups These instructions are designed for the following target groups The target groups must possess...

Страница 6: ...st be poured into the funnel The product can be inserted into a support manifold In this way the support manifold applies a vacuum to the product and filtration can be performed simultaneously The sup...

Страница 7: ...r cause hazards that are difficult to identify t Only operate the product when it is safe and in perfect working order 2 4 Spilled Liquids If liquids are spilled e g due to the product falling over or...

Страница 8: ...eceiver bottle example Pos Name Description 1 Lid Removable 2 Funnel For pouring in the liquid to be filtered Contains the membrane filter 3 Adapter Connects the funnel to the collection tube or the r...

Страница 9: ...connection of the vacuum filtration unit to a vacuum source The vacuum tube adapter holds the vacuum tube of the vacuum source 3 4 Vacuum Filtration The vacuum draws the liquids through the membrane...

Страница 10: ...ed individually in sterile packaging Exception For the non sterile versions the screw caps are included in the product packages The sterile screw cap must be unpacked immediately before use Procedure...

Страница 11: ...re supplied without a vacuum tube adapter 1 Fig 3 Product placed in a rack example Pos Name 1 Rack Material 1 rack or 1 holder for 50 mL centrifuge tubes Procedure t Insert the product into the chosen...

Страница 12: ...e vacuum source to the tube adapter The vacuum tube must not come loose during filtration 5 Use 5 1 Filling the Funnel CAUTION Danger of injury due to contamination of the vacuum source Excess liquid...

Страница 13: ...ons for the vacuum source or support manifold t Remove the product from the support manifold see instructions for the support manifold or pull the vacuum tube out off the tube adapter t Unscrew the fu...

Страница 14: ...ns on the proper decontamination and declaration for transport and disposal Procedure t If the product has come into contact with hazardous substances Decontaminate the product 7 2 Disposing of the Pr...

Страница 15: ...000 Sartolab RF500 Sartolab RF 1000 Unit Value Value Height mm 206 318 Outer diameter max mm 124 124 Product weight g 115 257 Sartolab BT 150 250 Sartolab BT 150 Sartolab BT 250 Unit Value Value Heigh...

Страница 16: ...0 100 Sartolab RF 150 10001 C 20 70 1 Storage at temperatures of 20 C 0 C is dependent on the liquid type and the storage conditions We recommend conducting a storage test for the solution before use...

Страница 17: ...ation Capacity Sartolab RF 50 250 Sartolab RF 50 Sartolab RF 50 Sartolab RF 50 Unit Value Value Value Type 180E01 2 180F01 2 180E01 E8 Filling volume max mL 50 50 50 Funnel volume mL 50 50 50 Receiver...

Страница 18: ...ab RF 1000 Sartolab RF 1000 Unit Value Value Type 180E05 E 180F05 E Filling volume max mL 1000 1000 Funnel volume mL 1000 1000 Receiver bottle volume mL 1000 1000 Hold up volume mL 4 1 4 1 Sartolab BT...

Страница 19: ...43 43 Pore size m 0 22 0 45 0 22 0 45 0 10 0 22 0 45 Membrane type PES Sartolab RF 500 1000 Sartolab RF 500 Sartolab RF 1000 Unit Value Value Membrane diameter mm 100 100 Effective filtration surface...

Страница 20: ...idually in sterile packaging Exception non sterile versions Sartolab RF 50 non sterile 180E01 E8 and 180F01 E8 Product not suitable for autoclaving 8 7 Approved Products 8 7 1 Receiver Bottle Sartolab...

Страница 21: ...PS Membrane Filter Polyethersulfone PES Collection tube Polypropylene PP Receiver bottle Polystyrene PS Adapter tube adapter screw cap Polyethylene HDPE Gasket vacuum filter installed in funnel Polye...

Страница 22: ...of the accessories that can be ordered For information on other products please contact Sartorius Item Quantity Order number Sartolab receiver bottle including screw cap 150 mL 12 180 22 E 250 mL 12...

Страница 23: ...feminine forms are used to facilitate legibility in these instructions and always simultaneously denote the other gender as well Copyright notice This instruction manual including all of its component...

Отзывы: