 RF | BT Instructions for Use

 

Process Preparation

4  Process Preparation

4.1 

Scope of Delivery

Item

Quantity

Product

Sartolab

®

 RF 50 sterile

24

Sartolab

®

 RF 50 non-sterile

96

Sartolab

®

 RF 150 – 1000  | Sartolab

®

 BT 150 – 1000

12

Vacuum tube adapter (sterile versions only)

24 or 12

Screw cap

Sartolab

®

 RF 50 sterile

24

Sartolab

®

 RF 50 non-sterile

96

Sartolab

®

 RF 150 – 1000

12

Quality certificate

1

Instructions for Use

1

4.2  Unpacking

The screw caps are packaged individually in sterile packaging. Exception: 
For the non-sterile versions, the screw caps are included in the product 
packages. The sterile screw cap must be unpacked immediately before use.

Procedure

 

X

Check the usability of the product (see specification on packaging). 
Dispose of products for which the usability has been exceeded.

 

X

Unpack the product.

4.3  Assembling the Receiver Bottle 

(Sartolab

®

 BT 150 – 1000 Only)

The product must be attached to a receiver bottle. The receiver bottle must 
be suitable for the product (see Chapter 8.7.1, page 20).

Material:

Receiver bottle of a suitable size x1

Procedure

 

X

Screw the product adapter onto the receiver bottle.

Содержание Sartolab BT 1000

Страница 1: ...Instructions for Use Sartolab RF BT RF 50 1000 BT 150 1000 Filtration Unit for Vacuum Filtration 1000096582...

Страница 2: ......

Страница 3: ...n 9 3 5 Product Symbols 9 4 Process Preparation 10 4 1 Scope of Delivery 10 4 2 Unpacking 10 4 3 Assembling the Receiver Bottle Sartolab BT 150 1000 Only 10 4 4 Inserting Product into a Rack Sartolab...

Страница 4: ...perating Conditions 16 8 4 1 Operating Pressure for Vacuum Source 16 8 4 2 Filtration Applications 16 8 4 3 Liquids 17 8 4 4 Filtration Capacity 17 8 5 Membrane Filter 19 8 6 Sterility 20 8 7 Approved...

Страница 5: ...E Sartolab BT 250 180E13 E Sartolab BT 500 180E14 E Sartolab BT 1000 180E15 E 180F15 E 1 2 Target Groups These instructions are designed for the following target groups The target groups must possess...

Страница 6: ...st be poured into the funnel The product can be inserted into a support manifold In this way the support manifold applies a vacuum to the product and filtration can be performed simultaneously The sup...

Страница 7: ...r cause hazards that are difficult to identify t Only operate the product when it is safe and in perfect working order 2 4 Spilled Liquids If liquids are spilled e g due to the product falling over or...

Страница 8: ...eceiver bottle example Pos Name Description 1 Lid Removable 2 Funnel For pouring in the liquid to be filtered Contains the membrane filter 3 Adapter Connects the funnel to the collection tube or the r...

Страница 9: ...connection of the vacuum filtration unit to a vacuum source The vacuum tube adapter holds the vacuum tube of the vacuum source 3 4 Vacuum Filtration The vacuum draws the liquids through the membrane...

Страница 10: ...ed individually in sterile packaging Exception For the non sterile versions the screw caps are included in the product packages The sterile screw cap must be unpacked immediately before use Procedure...

Страница 11: ...re supplied without a vacuum tube adapter 1 Fig 3 Product placed in a rack example Pos Name 1 Rack Material 1 rack or 1 holder for 50 mL centrifuge tubes Procedure t Insert the product into the chosen...

Страница 12: ...e vacuum source to the tube adapter The vacuum tube must not come loose during filtration 5 Use 5 1 Filling the Funnel CAUTION Danger of injury due to contamination of the vacuum source Excess liquid...

Страница 13: ...ons for the vacuum source or support manifold t Remove the product from the support manifold see instructions for the support manifold or pull the vacuum tube out off the tube adapter t Unscrew the fu...

Страница 14: ...ns on the proper decontamination and declaration for transport and disposal Procedure t If the product has come into contact with hazardous substances Decontaminate the product 7 2 Disposing of the Pr...

Страница 15: ...000 Sartolab RF500 Sartolab RF 1000 Unit Value Value Height mm 206 318 Outer diameter max mm 124 124 Product weight g 115 257 Sartolab BT 150 250 Sartolab BT 150 Sartolab BT 250 Unit Value Value Heigh...

Страница 16: ...0 100 Sartolab RF 150 10001 C 20 70 1 Storage at temperatures of 20 C 0 C is dependent on the liquid type and the storage conditions We recommend conducting a storage test for the solution before use...

Страница 17: ...ation Capacity Sartolab RF 50 250 Sartolab RF 50 Sartolab RF 50 Sartolab RF 50 Unit Value Value Value Type 180E01 2 180F01 2 180E01 E8 Filling volume max mL 50 50 50 Funnel volume mL 50 50 50 Receiver...

Страница 18: ...ab RF 1000 Sartolab RF 1000 Unit Value Value Type 180E05 E 180F05 E Filling volume max mL 1000 1000 Funnel volume mL 1000 1000 Receiver bottle volume mL 1000 1000 Hold up volume mL 4 1 4 1 Sartolab BT...

Страница 19: ...43 43 Pore size m 0 22 0 45 0 22 0 45 0 10 0 22 0 45 Membrane type PES Sartolab RF 500 1000 Sartolab RF 500 Sartolab RF 1000 Unit Value Value Membrane diameter mm 100 100 Effective filtration surface...

Страница 20: ...idually in sterile packaging Exception non sterile versions Sartolab RF 50 non sterile 180E01 E8 and 180F01 E8 Product not suitable for autoclaving 8 7 Approved Products 8 7 1 Receiver Bottle Sartolab...

Страница 21: ...PS Membrane Filter Polyethersulfone PES Collection tube Polypropylene PP Receiver bottle Polystyrene PS Adapter tube adapter screw cap Polyethylene HDPE Gasket vacuum filter installed in funnel Polye...

Страница 22: ...of the accessories that can be ordered For information on other products please contact Sartorius Item Quantity Order number Sartolab receiver bottle including screw cap 150 mL 12 180 22 E 250 mL 12...

Страница 23: ...feminine forms are used to facilitate legibility in these instructions and always simultaneously denote the other gender as well Copyright notice This instruction manual including all of its component...