98648-014-43
Installation Instructions
Sartorius PMA.Quality
PMA 7501-X|PMA 7501-X00V1|PMA 7501-X00W
Electronic Paint-mixing Scales for Zone 1
Страница 1: ...98648 014 43 Installation Instructions Sartorius PMA Quality PMA 7501 X PMA 7501 X00V1 PMA 7501 X00W Electronic Paint mixing Scales for Zone 1...
Страница 2: ...ng applications 8 c key Clear and REC key for paint mixing applications 9 L key ENTER and MEM key for paint mixing applications 10 Display 11 Weighing pan 12 Interfaces D Sub plug 9 contact 13 Connect...
Страница 3: ...rk on the equipment The standards regulations occupational safety requirements and environmental protection laws valid in your country must be observed It is important that all personnel using the equ...
Страница 4: ...mitted The bore hole is marked by a ground symbol If a bore hole is provided use a stainless steel screw and nut to connect the grounding conductor The wire used for the ground ing conductor should ha...
Страница 5: ...nd EN 60529 The casing on all connecting cables as well as the casing on wires inside the equipment housing is made of PVC The casing of the power cable is made of rubber Do not expose the scale to ag...
Страница 6: ...shipment Equipment Supplied Scale Weighing pan Power supply Setting Up the Scale Choose a suitable place to set up the scale Avoid exposure to drafts heat moisture and vibration Make sure to read the...
Страница 7: ...tomer Service for information on the legal regulations applicable in your country Use only genuine Sartorius power supplies The use of power supplies from other manufacturers even if these units have...
Страница 8: ...nents until the desired weight of your formula is reached Remove the filled paint can from the weighing pan Never use a hammer to close the lid of a paint can while it is still on the weighing pan Oth...
Страница 9: ...symbol appears in this case g Pour in additional components until the desired weight of your formula is reached Remove the filled paint can from the weighing pan Important Note If you zero the displa...
Страница 10: ...rtant Note The flashing arrow n on the display means that the weight value shown is not verified for use in legal metrology not legal for trade Example As you pour in the components of your formula th...
Страница 11: ...S key 4 When you then press the L key MEM 9 the scale will automatically calculate and display the amounts of paint in g to add for each of the other components that you already poured in This mode t...
Страница 12: ...es to correct the value to 200 0 g 10 Press the L key MEM 9 COR 01 11 1 Add the first component C1 is displayed 1 5 g 12 Pour in paint until 0 0 g is displayed 0 0 g 13 Press the L key MEM 9 COR 02 14...
Страница 13: ...r connection to AC power and before each calibration adjustment allow the scale to warm up for approx 30 min Hold down the U key 5 for 2 sec When 5000 is displayed release the key Center the calibrati...
Страница 14: ...l Press the L key ENTER to select the third level Level 3 The menu items in the third level Level 3 will be displayed Use the RS keys to select the desired menu item Press the L key ENTER to select th...
Страница 15: ...evel 1 Level 2 Level 3 Level 4 SETUP Press the L key ENTER APPLICATION RS keys select APPLICATION L key press ENTER Program RS keys select PROGRAM WIEIGH L key ENTER o TOGGLE RS keys select TOGGLE Pre...
Страница 16: ...enting further weighing operations The LOCK function is configured in the EXTRAS menu Level 1 Level 2 Level 3 Level 4 SETUP Press the L key ENTER EXTRAS RS keys select EXTRAS Press the L key ENTER LOC...
Страница 17: ...W will automatically appear You can now enter a new password or confirm each blinking dash by pressing the L key ENTER Blank spaces are then displayed Level 1 Level 2 Level 3 Level 4 INPUT RS keys sel...
Страница 18: ...t first be entered Level 1 Level 2 Level 3 Level 4 SETUP Press the L key ENTER RESET RS keys select RESET Press the L key ENTER MENU RS keys select MENU Press the L key ENTER YES Use the RS keys to se...
Страница 19: ...a changes constantly Too much vibration or Access the menu to select the scale is exposed to draft the appropriate code to adapt the scale to the particular weighing environment refer to Menu Settings...
Страница 20: ...longer ensured when There is visible damage to the power supply The equipment no longer functions properly The equipment has been stored for a relatively long period under unfavorable conditions The...
Страница 21: ...information about disposal and recycling options please contact your local service staff The partners listed on the following website can be used for disposals within the EU 1 Go to http www sartorius...
Страница 22: ...3 3 Calibration weight kg 5 class F2 or better Power consumption VA Average 8 maximum 16 Interface RS 232C Format 7 bit ASCII 1 start bit 1 or 2 stop bits Parity Even odd or no parity Transmission rat...
Страница 23: ...23 Accessories Order no In use dust cover YDC01PMA EX power supplies EC 609308 011 UK 609308 211 USA CDN 609308 61...
Страница 24: ...24...
Страница 25: ...25...
Страница 26: ...26...
Страница 27: ...27...
Страница 28: ...28...
Страница 29: ...29...
Страница 30: ...30...
Страница 31: ...31...
Страница 32: ...ductor 230 Vac Vo 12 6 V Io 230 mA Po 2 9 W Co 575 nF Lo 420 H 230 Vac 100 240 Vac Vi 8 7 V Ii 185 mA Pi 1 61 W Ci 5 6 F Li 0 Vo 8 7 V Io 185 mA Po 1 61 W Co 10 F for IIB Lo 5 H for IIB Sartorius cabl...
Страница 33: ...01 Y 1 Vo 11 8 V 2 Vi 12 6 V 2 23 6V 3 25 2 V 3 Io 123 mA Ii 131mA Po 361 mW Pi any Co 1 5 F 2 Ci 0 5 nF 129nF 3 Lo 2 mH Li 0 8 H Lo Ro 98 H ohm 2 98 H ohm 3 YDI05 Z Interface converter II 2 GD EEx ib...
Страница 34: ...Ex link box max length 100m RS 232 data output port1 Vi 12 6 V Vo 12 0 V Ii 132 mA Io 128 mA Pi 412 mW Po 376 mW Ci 2 nF Co 9 F Li 0 Lo 50 mH RS 232 data output port1 Vi 12 6 V 2 Vo 12 0 V 2 25 2 V 3...
Страница 35: ...35...
Страница 36: ...36...
Страница 37: ...37...
Страница 38: ......
Страница 39: ......
Страница 40: ...y means without the prior written permission of Sartorius The status of the information specifications and illustrations in this manual is indicated by the date given below Sartorius reserves the righ...