1
User Manual
-Installation -Operation
SR-1k-TL SR -1.5k-TL SR -2k-TL
Страница 1: ...1 User Manual Installation Operation SR 1k TL SR 1 5k TL SR 2k TL...
Страница 2: ...5 4 4 Further Information 5 Installation 16 5 1 Safety 16 5 2 Mounting Instructions 16 5 3 Safety Clearance 17 5 4 Mounting Procedure 18 5 4 1 Mounting with bracket 18 5 4 2 Mounting without bracket 2...
Страница 3: ...3 7 4 Instructions of Safety Standard selection when power up 37 7 5 State Information 39 8 Recycling and Disposal 40 9 Troubleshooting 41 10 Abbreviation 42 11 Contact...
Страница 4: ...r manual all time available in case of emergency 1 2 Symbols Used DANGER DANGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a...
Страница 5: ...re only for qualified personnel who are intended to install or uninstall the Grid Tie Solar Inverter WARNING Do not use this product unless it has been successfully installed by qualified personnel in...
Страница 6: ...tion service recycling and disposal of the inverters must be performed by qualified personnel only in compliance with national and local standards and regulations Please contact your dealer to get the...
Страница 7: ...generators and public grid Danger of hot surface The components inside the inverter will release a log of heat during operation DO NOT touch aluminum housing during operating An error has occurred Ple...
Страница 8: ...Product Safety Act in Europe Standards Association of Australian The inverter complies with the requirement of the AS4777 CE Mark Equipment with the CE mark fulfils the basic requirements of the Guid...
Страница 9: ...9 3 Product Information 3 1 Overview Industrial Layout Excellent Heat Elimination...
Страница 10: ...les more PV panels connected Wide MPP voltage range ensure high yield under various weather conditions High MPP tracking accuracy ensure the minimum power loses during converting Complete set of prote...
Страница 11: ...60Hz 50Hz 60Hz 50Hz 60Hz Max AC Current 5 8A 9 0A 12 0A Grid Voltage Range 185 276V 185 276V 185 276V Grid Frequency Range 45 55Hz 55 65Hz 45 55Hz 55 65Hz 45 55Hz 55 65Hz Power Factor 0 99 0 99 0 99 T...
Страница 12: ...P 65 According to IEC 60529 Cooling Concept Natural convection Mounting Information Wall Bracket General Data Operating Temperature Range 20 C to 60 C derating above 45 Relative Humidity 0 to 98 no co...
Страница 13: ...mpleteness for any visible external damage on the inverter or any accessories Contact your dealer if anything is damaged or missing A B C D E F G H Object Quantity Description A 1 inverter B 1 pair DC...
Страница 14: ...ance Front Bottom Object Description A Removable front shield B LED light Green RUN C LED light Red FAULT D LED light Yellow COM E Function key for displays and choice of language F Monitoring LCD wit...
Страница 15: ...cation You can identify the inverter by the side nameplate Information such as serial number SN type of the inverter as well as inverter specifications are specified on the side name plate The name pl...
Страница 16: ...H VOLTAGE power generation device the installation must be performed by qualified personnel only in compliance with national and local standards and regulations NOTICE NOTICE due to the inappropriate...
Страница 17: ...e device is properly fixed to the wall It is not recommended that the inverter is exposed to the strong sunshine because the excess heating might lead to power reduction The ambient temperature of ins...
Страница 18: ...wall according to the wall mounting bracket in the carton box Depth 50mm 250 213 First according to the marks drill 4 holes in the wall Then place four expansion tubes in the holes using a rubber hamm...
Страница 19: ...irst check the 4 holes in the backside of the inverter Then lift the inverter carefully align the 4 holes in the inverter and the 4 hooks on the bracket and finally attach the inverter to the hooks sl...
Страница 20: ...ccording to the paper installation position scale packed in the carton box 2 First according to the marks drill 4 holes in the wall Then place four expansion tubes in the holes using a rubber hammer N...
Страница 21: ...rter carefully align the 4 holes in the inverter and the 4 screws in the wall and finally attach the inverter to the screws slightly 4 Please carefully check the accessories and original carton to mak...
Страница 22: ...he inverter as the picture showed below 5 5 2 Safety lock without the wall mounting bracket After the inverter is hang up on the wall install the lock bracket on the aluminium radiator at the Lower Ri...
Страница 23: ...ckle Diameter 5 7 mm B Vertical Clearance 8 15 mm C Horizontal Clearance 12 20 mm Stainless solid hanger and secured lock cylinder NOTICE For further maintenance and possible repair please keep the ke...
Страница 24: ...ses PE connection DANGER DANGER to life due to potential fire or electricity shock With the inverter powered comply with all prevailing national regulations on accidents prevention This inverter will...
Страница 25: ...sor will detect the volume of the leakage current and compare it with the pre set value if the leakage current exceeds the permitted range the RCD will disconnect the inverter from the AC load 2 Assem...
Страница 26: ...g Then insert the stripped N L and PE cable accordingly to the corresponding position and fully tighten the screws e Aim the terminals on the straight plug to the holes of the grommet and then compres...
Страница 27: ...y instructions described here are disregarded then neither safety nor compliance with the technical data can be guaranteed For protection against electric shock PV connectors must be isolated from the...
Страница 28: ...r with sealing caps Plugged parts are watertight IP67 They can not be used permanently under water Do not lay the MC PV connectors on the roof surface See the MC catalogue 2 Solar line for technical d...
Страница 29: ...ill 3 Open end spanner PV MS 1 set 2 pieces Order No 32 6024 ill 4 PV WZ AD GWD socket wrench insert to tighten Order No 32 6006 ill 5 PV SSE AD4 socket wrench insert to secure PV SSE AD4 Order No 32...
Страница 30: ...tion may exceed the permitted limits Check dimension b according to the following table ill 10 Strip cable insulation L 6 7 5 mm Take care not to cut individual strands Recommended tool Stripping plie...
Страница 31: ...ning torque must be adapted to the solar cables used in each specific case Typical values lie in a range between 2 5 Nm to 3 Nm Plugging and unplugging the cable coupler without safety lock clip PV SS...
Страница 32: ...communications that is up to 50 inverters can be connected one by one through these 2 plugs and the cables the upper computer can communicate with these inverters via a single signal cable at the sam...
Страница 33: ...it is easy for user to check and set the data In addition the user can press the function key to illuminate the LCD screen NOTICE Inverter is not an aligned measuring instrument for current voltage or...
Страница 34: ...Pac xxxx W The top line Line 1 shows current state information by default and by pressing function key it will display different operating information as the following flow chart and table NOTICE Mak...
Страница 35: ...xxxx W Iac Pac xxxx W E total Pac xxxx W Vpv Pac xxxx W Ipv Pac xxxx W E today Pac xxxx W Vac Pac xxxx W Model Pac xxxx W Ver Pac xxxx W Set language Pac xxxx W Frequency Pac xxxx W S N WiFi Pac xxxx...
Страница 36: ...Firmware version Set Language Several languages are provided for users reference to 7 3 for further information Vac The grid voltage S N WiFi Displays the serial number of the WiFi card such as no Wi...
Страница 37: ...verters Only perform this operation when the accumulative generated electricity is less than 1KWh 2 Operation steps are as following a Power on the inverter with only DC side connected while disconnec...
Страница 38: ...38 c When the LCD displays your desired Safety Standard hold the Function button for 5 seconds or more until it shows Safety Standard OK d The Safety Standard setup is now completed...
Страница 39: ...y Loss No Utility Island PV Over Voltage Input voltage too high Over Temperature Temperature abnormal Isolation Fault Isolation failure Relay Check Fail Output relay failure DC INJ High Output DC inje...
Страница 40: ...the end of its life must be collected separately and returned to an approved recycling facility Any device that you no longer required must be returned to your dealer or you must find an approved coll...
Страница 41: ...y Loss 1 Grid is not connected 2 Check grid connection cables 3 Check grid usability 4 If grid is ok and the problem persists maybe the fuse in the inverter is open please call service Over Temperatur...
Страница 42: ...aximum Power Point Impp Amperage at Maximum Power Point AC Alternating Current Form of electricity supplied by Utility Company DC Direct Current Form of electricity generated by PV modules VDE 0126 1...