1 ELECTRICAL SYSTEM USING PSU 2006
1.1 INTRODUCTION
For the safe operation of all electrical equipment within your Caravan / Motorhome / Trailer Tent /
Folding Camper it is important that you read and fully understand these instructions. If you are unsure
of any point please contact your dealer / distributor for advice before use.
Your Caravan / Motorhome / Trailer Tent / Folding Camper has been fitted with an electrical system
from Sargent Electrical Services Ltd. and incorporates the new PSU2006 power supply. This unit
provides protection for the 240v (mains) and 12v equipment, supplies 12v power and charges the
internal leisure battery. The electrical system complies with EN 1648-1 & -2 and BS7671.
1.2 MAINS CONNECTION
For your safety it is
IMPORTANT
that you follow these connections instructions each time your
Caravan / Motorhome / Trailer Tent / Folding Camper is connected to a mains supply.
A)
Ensure suitability of the Mains Supply
. Your Caravan / Motorhome / Trailer Tent / Folding
Camper should only be connected to an approved supply that meets the requirements of BS7671.
In most cases the site warden will hold information regarding suitability of supply. If using a
generator you also need to comply with the requirements / instructions supplied with the generator.
B)
Switch the PSU2006 unit OFF
. Locate the red power switch on the PSU2006 and ensure the
switch is in the OFF (0) position before connection to the mains supply.
C)
Connect the Hook-up Lead
. Firstly connect the supplied hook-up lead (orange cable with blue
connectors) to the Caravan / Motorhome / Trailer Tent / Folding Camper and then connect to the
mains supply.
D)
Check Residual Current Device operation
. Locate the RCD within the PSU2006 and ensure the
RCD is switched on (lever in up position). Press the ‘TEST’ button and confirm that the RCD is
turned off (lever in down position). Switch the RCD back to the on position (lever in up position). If
the test button failed to operate the RCD see section 1.4.
E)
Check correct Polarity
. Locate the ‘Reverse Polarity’ indicator on the PSU2006 and ensure that
the indicator is NOT illuminated. If the indicator is illuminated see section 1.4.
F)
Check Miniature Circuit Breakers
. Locate the MCB’s within the PSU2006 (adjacent to the RCD)
and ensure they are all in the ON (up) position.
G)
Turn the PSU2006 ON
. Locate the red power switch on the PSU2006 and turn to the ON (I)
position. The switch will illuminate when turned on.
H)
Check operation of equipment
. It is now safe to check the operation of the 12v and 240v
equipment.
PSU 2006 Layout
PSU 2006 Specification
Mains Input 230 Volts AC +/- 10%
Frequency 50 Hz
Output Voltage 13.5 Volts nominal
Output Current 12 Amps nominal
(150 Watts)